Search Results (463 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-21924 2026-04-15 8.2 High
SMM callout vulnerability within the AmdPlatformRasSspSmm driver could allow a ring 0 attacker to modify boot services handlers, potentially resulting in arbitrary code execution.
CVE-2025-32802 1 Redhat 1 Enterprise Linux 2026-04-15 6.1 Medium
Kea configuration and API directives can be used to overwrite arbitrary files, subject to permissions granted to Kea. Many common configurations run Kea as root, leave the API entry points unsecured by default, and/or place the control sockets in insecure paths. This issue affects Kea versions 2.4.0 through 2.4.1, 2.6.0 through 2.6.2, and 2.7.0 through 2.7.8.
CVE-2025-42958 1 Sap 2 Netweaver, Sap Netweaver 2026-04-15 9.1 Critical
Due to a missing authentication check in the SAP NetWeaver application on IBM i-series, the application allows high privileged unauthorized users to read, modify, or delete sensitive information, as well as access administrative or privileged functionalities. This results in a high impact on the confidentiality, integrity, and availability of the application.
CVE-2024-50590 1 Hasomed 1 Elefant 2026-04-15 7.8 High
Attackers with local access to the medical office computer can escalate their Windows user privileges to "NT AUTHORITY\SYSTEM" by overwriting one of two Elefant service binaries with weak permissions. The default installation directory of Elefant is "C:\Elefant1" which is writable for all users. In addition, the Elefant installer registers two Firebird database services which are running as “NT AUTHORITY\SYSTEM”.  Path: C:\Elefant1\Firebird_2\bin\fbserver.exe Path: C:\Elefant1\Firebird_2\bin\fbguard.exe Both service binaries are user writable. This means that a local attacker can rename one of the service binaries, replace the service executable with a new executable, and then restart the system. Once the system has rebooted, the new service binary is executed as "NT AUTHORITY\SYSTEM".
CVE-2024-43651 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y).
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43650 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects  firmware versions before 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: The attack can be executed over any network connection serving the web interface (AV:N). There are no additional measures that need to be circumvented (AC:L) or attack preconditions (AT:N). THe attack is privileged, but the level does not matter (PR:L) and does not require user interaction (UI:N). Attack leads to full system compromised (VC:H/VI:H/VA:H) and compromised devices can be used to "pivot" to other networks that should be unreachable (SC:L/SI:L/SA:H). Because this an EV charger using high power, there is a potential safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-50505 1 Clash-verge 1 Clash-verge 2026-04-15 7.8 High
Clash Verge Rev thru 2.2.3 (fixed in 2.3.0) forces the installation of system services(clash-verge-service) by default and exposes key functions through the unauthorized HTTP API `/start_clash`, allowing local users to submit arbitrary bin_path parameters and pass them directly to the service process for execution, resulting in local privilege escalation.
CVE-2024-28139 2026-04-15 8.8 High
The www-data user can elevate its privileges because sudo is configured to allow the execution of the mount command as root without a password. Therefore, the privileges can be escalated to the root user. The risk has been accepted by the vendor and won't be fixed in the near future.
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2026-4498 1 Elastic 1 Kibana 2026-04-14 7.7 High
Execution with Unnecessary Privileges (CWE-250) in Kibana’s Fleet plugin debug route handlers can lead reading index data beyond their direct Elasticsearch RBAC scope via Privilege Abuse (CAPEC-122). This requires an authenticated Kibana user with Fleet sub-feature privileges (such as agents, agent policies, and settings management).
CVE-2026-1346 1 Ibm 4 Security Verify Access, Security Verify Access Container, Verify Identity Access and 1 more 2026-04-10 9.3 Critical
IBM Verify Identity Access Container 11.0 through 11.0.2 and IBM Security Verify Access Container 10.0 through 10.0.9.1 and IBM Verify Identity Access 11.0 through 11.0.2 and IBM Security Verify Access 10.0 through 10.0.9.1 could allow a locally authenticated user to escalate their privileges to root due to execution with unnecessary privileges than required.
CVE-2024-23299 1 Apple 1 Macos 2026-04-02 8.6 High
The issue was addressed with improved checks. This issue is fixed in macOS Monterey 12.7.4, macOS Sonoma 14.4, macOS Ventura 13.6.5. An app may be able to break out of its sandbox.
CVE-2026-4606 1 Geovision 1 Gv-edge Recording Manager 2026-03-25 N/A
GV Edge Recording Manager (ERM) v2.3.1 improperly runs application components with SYSTEM-level privileges, allowing any local user to gain full control of the operating system.  During installation, ERM creates a Windows service that runs under the LocalSystem account.  When the ERM application is launched, related processes are spawned under SYSTEM privileges rather than the security context of the logged-in user.  Functions such as 'Import Data' open a Windows file dialog operating with SYSTEM permissions, enabling modification or deletion of protected system files and directories.  Any ERM function invoking Windows file open/save dialogs exposes the same risk.  This vulnerability allows local privilege escalation and may result in full system compromise.
CVE-2025-34515 1 Ilevia 2 Eve X1 Server, Eve X1 Server Firmware 2026-03-23 9.8 Critical
Ilevia EVE X1 Server firmware versions ≤ 4.7.18.0.eden contain an execution with unnecessary privileges vulnerability in sync_project.sh that allows an attacker to escalate privileges to root. Ilevia has declined to service this vulnerability, and recommends that customers not expose port 8080 to the internet.
CVE-2025-69783 2 Comodosecurity, Xcitium 2 Openedr, Openedr 2026-03-23 7.8 High
A local attacker can bypass OpenEDR's 2.5.1.0 self-defense mechanism by renaming a malicious executable to match a trusted process name (e.g., csrss.exe, edrsvc.exe, edrcon.exe). This allows unauthorized interaction with the OpenEDR kernel driver, granting access to privileged functionality such as configuration changes, process monitoring, and IOCTL communication that should be restricted to trusted components. While this issue alone does not directly grant SYSTEM privileges, it breaks OpenEDR's trust model and enables further exploitation leading to full local privilege escalation.
CVE-2025-67510 2 Neuron-ai, Neuron-core 2 Neuron, Neuron-ai 2026-03-06 9.4 Critical
Neuron is a PHP framework for creating and orchestrating AI Agents. In versions 2.8.11 and below, the MySQLWriteTool executes arbitrary SQL provided by the caller using PDO::prepare() + execute() without semantic restrictions. This is consistent with the name (“write tool”), but in an LLM/agent context it becomes a high-risk capability: prompt injection or indirect prompt manipulation can cause execution of destructive queries such as DROP TABLE, TRUNCATE, DELETE, ALTER, or privilege-related statements (subject to DB permissions). Deployments that expose an agent with MySQLWriteTool enabled to untrusted input and/or run the tool with a DB user that has broad privileges are impacted. This issue is fixed in version 2.8.12.
CVE-2024-48013 1 Dell 1 Smartfabric Os10 2026-02-26 8.8 High
Dell SmartFabric OS10 Software, version(s) 10.5.4.x, 10.5.5.x, 10.5.6.x, 10.6.0.x, contain(s) an Execution with Unnecessary Privileges vulnerability. A low privileged attacker with remote access could potentially exploit this vulnerability, leading to Elevation of privileges.
CVE-2025-1137 1 Ibm 2 Spectrum Scale Container Native Storage Access, Storage Scale 2026-02-26 7.5 High
IBM Storage Scale 5.2.2.0 and 5.2.2.1, under certain configurations, could allow an authenticated user to execute privileged commands due to improper input neutralization.
CVE-2025-1951 1 Ibm 2 Hardware Management Console, Power Hardware Management Console 2026-02-26 8.4 High
IBM Hardware Management Console - Power Systems V10.2.1030.0 and V10.3.1050.0 could allow a local user to execute commands as a privileged user due to execution of commands with unnecessary privileges.