Export limit exceeded: 364285 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (2289 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-40816 1 Siemens 2 Logo!, Siplus Logo! 2026-04-15 7.6 High
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVE-2024-22041 1 Siemens 13 Cerberus Pro En Engineering Tool, Cerberus Pro En Fire Panel Fc72x, Cerberus Pro En X200 Cloud Distribution and 10 more 2026-04-15 7.5 High
A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions), Cerberus PRO EN Fire Panel FC72x IP6 (All versions), Cerberus PRO EN Fire Panel FC72x IP7 (All versions), Cerberus PRO EN Fire Panel FC72x IP8 (All versions < IP8 SR4), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.3.5618), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.3.5617), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions), Sinteso FS20 EN Fire Panel FC20 MP8 (All versions < MP8 SR4), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.3.5618), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.3.5617), Sinteso Mobile (All versions). The network communication library in affected systems improperly handles memory buffers when parsing X.509 certificates. This could allow an unauthenticated remote attacker to crash the network service.
CVE-2024-32014 1 Siemens 1 Spectrum Power 4 2026-04-15 4.7 Medium
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to alter the local database which contains the application credentials. This allows an attacker to gain administrative application privileges.
CVE-2024-32639 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVE-2024-44087 1 Siemens 1 Automation License Manager 2026-04-15 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2023-50821 1 Siemens 3 Simatic Pcs 7, Simatic Wincc, Simatic Wincc Runtime Professional 2026-04-15 6.2 Medium
A vulnerability has been identified in SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC04), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 1), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 16), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products do not properly validate the input provided in the login dialog box. An attacker could leverage this vulnerability to cause a persistent denial of service condition.
CVE-2024-52335 1 Siemens 1 Syngo Plaza Vb30e 2026-04-15 9.8 Critical
A vulnerability has been identified in syngo.plaza VB30E (All versions < VB30E_HF05). The affected application do not properly sanitize input data before sending it to the SQL server. This could allow an attacker with access to the application could use this vulnerability to execute malicious SQL commands to compromise the whole database.
CVE-2024-32008 1 Siemens 1 Spectrum Power 4 2026-04-15 7.8 High
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP12 Update 2). The affected application is vulnerable to a local privilege escalation due to an exposed debug interface on the localhost. This allows any local user to gain code execution as administrative application user.
CVE-2025-40743 1 Siemens 4 Sinumerik 828d, Sinumerik 840d Sl, Sinumerik Mc and 1 more 2026-04-15 8.3 High
A vulnerability has been identified in SINUMERIK 828D PPU.4 (All versions < V4.95 SP5), SINUMERIK 828D PPU.5 (All versions < V5.25 SP1), SINUMERIK 840D sl (All versions < V4.95 SP5), SINUMERIK MC (All versions < V1.25 SP1), SINUMERIK MC V1.15 (All versions < V1.15 SP5), SINUMERIK ONE (All versions < V6.25 SP1), SINUMERIK ONE V6.15 (All versions < V6.15 SP5). The affected application improperly validates authentication for its VNC access service, allowing access with insufficient password verification. This could allow an attacker to gain unauthorized remote access and potentially compromise system confidentiality, integrity, or availability.
CVE-2024-35783 1 Siemens 6 Simatic Batch, Simatic Information Server, Simatic Pcs7 and 3 more 2026-04-15 9.1 Critical
A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges.
CVE-2020-28398 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 8.8 High
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The CLI feature in the web interface of affected devices is vulnerable to cross-site request forgery (CSRF). This could allow an attacker to read or modify the device configuration by tricking an authenticated legitimate user into accessing a malicious link.
CVE-2025-33023 1 Siemens 11 Ruggedcom Rox Mx5000, Ruggedcom Rox Mx5000re, Ruggedcom Rox Rx1400 and 8 more 2026-04-15 4.1 Medium
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions), RUGGEDCOM ROX MX5000RE (All versions), RUGGEDCOM ROX RX1400 (All versions), RUGGEDCOM ROX RX1500 (All versions), RUGGEDCOM ROX RX1501 (All versions), RUGGEDCOM ROX RX1510 (All versions), RUGGEDCOM ROX RX1511 (All versions), RUGGEDCOM ROX RX1512 (All versions), RUGGEDCOM ROX RX1524 (All versions), RUGGEDCOM ROX RX1536 (All versions), RUGGEDCOM ROX RX5000 (All versions). The affected devices do not properly enforce the restriction of files that can be uploaded from the web interface. This could allow an authenticated remote attacker with high privileges in the web interface to upload arbitrary files.
CVE-2025-40820 1 Siemens 16 Sidoor Atd430w, Sidoor Ate530s Coated, Simatic and 13 more 2026-04-15 7.5 High
Affected products do not properly enforce TCP sequence number validation in specific scenarios but accept values within a broad range. This could allow an unauthenticated remote attacker e.g. to interfere with connection setup, potentially leading to a denial of service. The attack succeeds only if an attacker can inject IP packets with spoofed addresses at precisely timed moments, and it affects only TCP-based services.
CVE-2026-27664 1 Siemens 2 Cpci85 Central Processing\/communication, Sicore Base System 2026-04-14 7.5 High
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), SICORE Base system (All versions < V26.10.0). The affected application contains an out-of-bounds write vulnerability while parsing specially crafted XML inputs. This could allow an unauthenticated attacker to exploit this issue by sending a malicious XML request, which may cause the service to crash, resulting in a denial-of-service condition.
CVE-2026-27663 1 Siemens 2 Cpci85 Central Processing\/communication, Rtum85 rtu Base 2026-04-14 6.5 Medium
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V26.10), RTUM85 RTU Base (All versions < V26.10). The affected application contains denial-of-service (DoS) vulnerability. The remote operation mode is susceptible to a resource exhaustion condition when subjected to a high volume of requests. Sending multiple requests can exhaust resources, preventing parameterization and requiring a reset or reboot to restore functionality.
CVE-2020-26147 5 Arista, Debian, Linux and 2 more 15 C-65, C-65 Firmware, C-75 and 12 more 2026-04-14 5.4 Medium
An issue was discovered in the Linux kernel 5.8.9. The WEP, WPA, WPA2, and WPA3 implementations reassemble fragments even though some of them were sent in plaintext. This vulnerability can be abused to inject packets and/or exfiltrate selected fragments when another device sends fragmented frames and the WEP, CCMP, or GCMP data-confidentiality protocol is used.
CVE-2023-44373 1 Siemens 142 6ag1206-2bb00-7ac2, 6ag1206-2bb00-7ac2 Firmware, 6ag1206-2bs00-7ac2 and 139 more 2026-04-14 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell. Follow-up of CVE-2022-36323.
CVE-2022-36325 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2026-04-14 6.8 Medium
Affected devices do not properly sanitize data introduced by an user when rendering the web interface. This could allow an authenticated remote attacker with administrative privileges to inject code and lead to a DOM-based XSS.
CVE-2022-36324 1 Siemens 168 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 165 more 2026-04-14 7.5 High
Affected devices do not properly handle the renegotiation of SSL/TLS parameters. This could allow an unauthenticated remote attacker to bypass the TCP brute force prevention and lead to a denial of service condition for the duration of the attack.
CVE-2022-36323 1 Siemens 180 Scalance M-800, Scalance M-800 Firmware, Scalance S615 and 177 more 2026-04-14 9.1 Critical
Affected devices do not properly sanitize an input field. This could allow an authenticated remote attacker with administrative privileges to inject code or spawn a system root shell.