Search Results (1006 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-1060 2026-04-15 7.5 High
CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists that could result in the exposure of data when network traffic is being sniffed by an attacker.
CVE-2024-45102 1 Lenovo 1 Xclarity Administrator 2026-04-15 6.8 Medium
A privilege escalation vulnerability was discovered that could allow a valid, authenticated LXCA user to escalate their permissions for a connected XCC instance when using LXCA as a Single Sign On (SSO) provider for XCC instances.
CVE-2025-61738 1 Johnsoncontrols 5 Iq Panels2, Iq Panels2+, Iqhub and 2 more 2026-04-15 N/A
Under certain circumstances, attacker can capture the network key, read or write encrypted packets on the PowerG network.
CVE-2024-12378 2026-04-15 9.1 Critical
On affected platforms running Arista EOS with secure Vxlan configured, restarting the Tunnelsec agent will result in packets being sent over the secure Vxlan tunnels in the clear.
CVE-2024-41124 2026-04-15 6.3 Medium
Puncia is the Official CLI utility for Subdomain Center & Exploit Observer. `API_URLS` is utilizing HTTP instead of HTTPS for communication that can lead to issues like Eavesdropping, Data Tampering, Unauthorized Data Access & MITM Attacks. This issue has been addressed in release version 0.21 by using https rather than http connections. All users are advised to upgrade. There is no known workarounds for this vulnerability.
CVE-2025-12508 2 Bizerba, Microsoft 2 Brain2, Active Directory 2026-04-15 8.4 High
When using domain users as BRAIN2 users, communication with Active Directory services is unencrypted. This can lead to the interception of authentication data and compromise confidentiality.
CVE-2020-36914 1 Qihang Media 1 Web Digital Signage 2026-04-15 7.5 High
QiHang Media Web Digital Signage 3.0.9 contains a sensitive information disclosure vulnerability that allows remote attackers to intercept user authentication credentials through cleartext cookie transmission. Attackers can perform man-in-the-middle attacks to capture and potentially misuse stored authentication credentials transmitted in an insecure manner.
CVE-2025-52586 1 Eg4 Electronics 7 Eg4 12000xp, Eg4 12kpv, Eg4 18kpv and 4 more 2026-04-15 6.9 Medium
The MOD3 command traffic between the monitoring application and the inverter is transmitted in plaintext without encryption or obfuscation. This vulnerability may allow an attacker with access to a local network to intercept, manipulate, replay, or forge critical data, including read/write operations for voltage, current, and power configuration, operational status, alarms, telemetry, system reset, or inverter control commands, potentially disrupting power generation or reconfiguring inverter settings.
CVE-2025-27594 2026-04-15 7.5 High
The device uses an unencrypted, proprietary protocol for communication. Through this protocol, configuration data is transmitted and device authentication is performed. An attacker can thereby intercept the authentication hash and use it to log into the device using a pass-the-hash attack.
CVE-2025-10776 1 Lioncoders 1 Salepro Pos 2026-04-15 3.7 Low
A vulnerability was detected in LionCoders SalePro POS up to 5.5.0. This issue affects some unknown processing of the component Login. Performing manipulation results in cleartext transmission of sensitive information. The attack can be initiated remotely. The attack is considered to have high complexity. The exploitability is assessed as difficult. The exploit is now public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2025-47419 2026-04-15 N/A
Cleartext Transmission of Sensitive Information vulnerability in Crestron Automate VX allows Sniffing Network Traffic. The device allows Web UI and API access over non-secure network ports which exposes sensitive information such as user passwords. This issue affects Automate VX: from 5.6.8161.21536 through 6.4.0.49.
CVE-2025-6180 1 Strongdm 1 Sdm-cli 2026-04-15 N/A
The StrongDM Client insufficiently protected a pre-authentication token. Attackers could exploit this to intercept and reuse the token, potentially redeeming valid authentication credentials through a race condition.
CVE-2025-47698 1 Cognex 1 In-sight Explorer 2026-04-15 N/A
An adjacent attacker without authentication can exploit this vulnerability to retrieve a set of user-privileged credentials. These credentials are present during the firmware upgrade procedure.
CVE-2025-41718 1 Murrelektronik 4 Firmware Impact67 Pro 54620, Firmware Impact67 Pro 54630, Firmware Impact67 Pro 54631 and 1 more 2026-04-15 7.5 High
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
CVE-2025-22493 2026-04-15 5.6 Medium
Secure flag not set and SameSIte was set to Lax in the Foreseer Reporting Software (FRS). Absence of this secure flag could lead into the session cookie being transmitted over unencrypted HTTP connections. This security issue has been resolved in the latest version of FRS v1.5.100.
CVE-2024-46505 2026-04-15 9.1 Critical
Infoblox BloxOne v2.4 was discovered to contain a business logic flaw due to thick client vulnerabilities.
CVE-2025-56447 1 Tm2 1 Monitoring 2026-04-15 9.8 Critical
TM2 Monitoring v3.04 contains an authentication bypass and plaintext credential disclosure.
CVE-2024-40595 1 Oneidentity 1 Safeguard For Privileged Sessions 2026-04-15 5.3 Medium
An authentication-bypass issue in the RDP component of One Identity Safeguard for Privileged Sessions (SPS) On Premise before 7.5.1 (and LTS before 7.0.5.1) allows man-in-the-middle attackers to obtain access to privileged sessions on target resources by intercepting cleartext RDP protocol information.
CVE-2025-42603 2026-04-15 N/A
This vulnerability exists in the Meon KYC solutions due to transmission of sensitive data in plain text within the response payloads of certain API endpoints. An authenticated remote attacker could exploit this vulnerability by intercepting API response that contains unencrypted sensitive information belonging to other users. Successful exploitation of this vulnerability could allow remote attacker to impersonate the target user and gain unauthorized access to the user account.
CVE-2024-45361 2 Mi, Xiaomi 2 Xiaomi, Mi Connect Service 2026-04-15 6.5 Medium
A protocol flaw vulnerability exists in the Xiaomi Mi Connect Service APP. The vulnerability is caused by the validation logic is flawed and can be exploited by attackers to leak sensitive user information.