CVE Vendors Products Updated CVSS v3.1
CVE-2025-10365 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10364 1 Evertz 1 3080ipx 2026-04-15 N/A
The Evertz SDVN 3080ipx-10G is a High Bandwidth Ethernet Switching Fabric for Video Application. This device exposes a web management interface on port 80. This web management interface can be used by administrators to control product features, setup network switching, and register license among other features. The application has been developed in PHP with the webEASY SDK, also named ‘ewb’ by Evertz. This web interface has two endpoints that are vulnerable to arbitrary command injection (CVE-2025-4009, CVE-2025-10364) and the authentication mechanism has a flaw leading to authentication bypass (CVE-2025-10365). CVE-2025-4009 covers the command injection in feature-transfer-import.php CVE-2025-10364 covers the command injection in feature-transfer-export.php Remote unauthenticated attackers can gain arbitrary command execution with elevated privileges ( root ) on affected devices. This level of access could lead to serious business impact such as the interruption of media streaming, modification of media being streamed, alteration of closed captions being generated, among others.
CVE-2025-10363 1 Microsoft 1 Windows 2026-04-15 N/A
Deserialization of Untrusted Data vulnerability in Topal Solutions AG Topal Finanzbuchhaltung on Windows allows Remote Code Execution.This issue affects at least Topal Finanzbuchhaltung: 10.1.5.20 and is fixed in version 11.2.12.00
CVE-2024-45480 2026-04-15 N/A
An improper control of generation of code ('Code Injection') vulnerability in the AprolCreateReport component of B&R APROL <4.4-00P5 may allow an unauthenticated network-based attacker to read files from the local system.
CVE-2024-45369 1 Myscada 2 Mypro Manager, Mypro Runtime 2026-04-15 8.1 High
The web application uses a weak authentication mechanism to verify that a request is coming from an authenticated and authorized resource.
CVE-2024-44087 1 Siemens 1 Automation License Manager 2026-04-15 8.6 High
A vulnerability has been identified in Automation License Manager V5 (All versions), Automation License Manager V6.0 (All versions < V6.0 SP12 Upd3), Automation License Manager V6.2 (All versions < V6.2 Upd3). Affected applications do not properly validate certain fields in incoming network packets on port 4410/tcp. This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-4332 1 Fortra 1 Tripwire Enterprise 2026-04-15 N/A
An authentication bypass vulnerability has been identified in the REST and SOAP API components of Tripwire Enterprise (TE) 9.1.0 when TE is configured to use LDAP/Active Directory SAML authentication and its optional "Auto-synchronize LDAP Users, Roles, and Groups" feature is enabled. This vulnerability allows unauthenticated attackers to bypass authentication if a valid username is known. Exploitation of this vulnerability could allow remote attackers to gain privileged access to the APIs and lead to unauthorized information disclosure or modification.
CVE-2025-66266 1 Megatec 1 Upsilon2000 2026-04-15 N/A
The RupsMon.exe service executable in UPSilon 2000 has insecure permissions, allowing the 'Everyone' group Full Control. A local attacker can replace the executable with a malicious binary to execute code with SYSTEM privileges or simply change the config path of the service to a command; starting and stopping the service to immediately achieve code execution and privilege escalation
CVE-2024-41798 1 Siemens 1 Sentron Pac3200 2026-04-15 9.8 Critical
A vulnerability has been identified in SENTRON 7KM PAC3200 (All versions). Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface could easily bypass this protection by brute-force attacks or by sniffing the Modbus clear text communication.
CVE-2025-10659 1 Megasys 1 Telenium Online Web Application 2026-04-15 9.8 Critical
The Telenium Online Web Application is vulnerable due to a PHP endpoint accessible to unauthenticated network users that improperly handles user-supplied input. This vulnerability occurs due to the insecure termination of a regular expression check within the endpoint. Because the input is not correctly validated or sanitized, an unauthenticated attacker can inject arbitrary operating system commands through a crafted HTTP request, leading to remote code execution on the server in the context of the web application service account.
CVE-2025-5597 2026-04-15 N/A
Improper Authentication vulnerability in WF Steuerungstechnik GmbH airleader MASTER allows Authentication Bypass.This issue affects airleader MASTER: 3.00571.
CVE-2025-5598 2026-04-15 N/A
Path Traversal vulnerability in WF Steuerungstechnik GmbH airleader MASTER allows Retrieve Embedded Sensitive Data.This issue affects airleader MASTER: 3.0046.
CVE-2025-53883 1 Suse 4 Container Suse Manager 5.0, Manager, Manager Server and 1 more 2026-04-15 N/A
A Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS) vulnerability allows attackers to run arbitrary javascript via a reflected XSS issue in the search fields.This issue affects Container suse/manager/5.0/x86_64/server:latest: from ? before 5.0.28-150600.3.36.8; SUSE Manager Server LTS 4.3: from ? before 4.3.88-150400.3.113.5.
CVE-2025-9265 1 Kiloview 1 Ndi N30 2026-04-15 N/A
A broken authorization vulnerability in Kiloview NDI N30 allows a remote unauthenticated attacker to deactivate user verification, giving them access to state changing actions that should only be initiated by administratorsThis issue affects Kiloview NDI N30 and was fixed in Firmware version later than 2.02.0246
CVE-2024-37998 2026-04-15 9.8 Critical
A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). The password of administrative accounts of the affected applications can be reset without requiring the knowledge of the current password, given the auto login is enabled. This could allow an unauthorized attacker to obtain administrative access of the affected applications.