| The affected product permits OS command injection through improperly restricted commands, potentially allowing attackers to execute arbitrary code. |
| UD-LT1 firmware Ver.2.1.9 and earlier and UD-LT1/EX firmware Ver.2.1.9 and earlier allow a remote authenticated attacker with an administrative account to execute arbitrary OS commands. |
| A parameter within a command does not properly validate input within myPRO Manager which could be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands. |
| A command execution vulnerability exists in the AX2 Pro home router produced by Shenzhen Tenda Technology Co., Ltd. (Jixiang Tenda) v.DI_7003G-19.12.24A1V16.03.29.50;V16.03.29.50;V16.03.29.50. An attacker can exploit this vulnerability by constructing a malicious payload to execute commands and further obtain shell access to the router's file system with the highest privileges. |
| Out-of-bounds write vulnerability exists in DocuPrint CP225w 01.22.01 and earlier, DocuPrint CP228w 01.22.01 and earlier, DocuPrint CM225fw 01.10.01 and earlier, and DocuPrint CM228fw 01.10.01 and earlier. If an affected MFP processes a specially crafted printer job file, a denial-of-service (DoS) condition may occur. |
| A missing null-termination character in the last element of an nvlist array string can lead to writing outside the allocated buffer. |
| Elsight – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') |
| Gigastone TR1 Travel Router R101 v1.0.2 is vulnerable to Command Injection. This allows an authenticated attacker to execute arbitrary commands on the device by sending a crafted HTTP request to the ssid parameter in the request. |
| A vulnerability in the “Remote Logging” functionality of the web application of ctrlX OS allows a remote authenticated (low-privileged) attacker to execute arbitrary OS commands in the context of user “root” via a crafted HTTP request. |
| The theme.php file in SDCMS 2.8 has a command execution vulnerability that allows for the execution of system commands |
| An OS Command Injection vulnerability exists within myPRO Manager. A parameter within a command can be exploited by an unauthenticated remote attacker to inject arbitrary operating system commands. |
| OS command injection vulnerability in multiple digital video recorders provided by TAKENAKA ENGINEERING CO., LTD. allows a remote authenticated attacker to execute an arbitrary OS command on the device or alter the device settings. |
| The affected product is vulnerable to a command injection. An unauthenticated attacker could send commands through a malicious HTTP request which could result in remote code execution. |
| cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root
This issue affects Iocharger firmware for AC model chargers before version 24120701.
Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| An issue was discovered in Victure RX1800 WiFi 6 Router (software EN_V1.0.0_r12_110933, hardware 1.0) devices. The /cgi-bin/luci/admin/opsw/Dual_freq_un_apple endpoint is vulnerable to command injection through the 2.4 GHz and 5 GHz name parameters, allowing an attacker to execute arbitrary commands on the device (with root-level permissions) via crafted input. |
| An issue was discovered in Victure RX1800 WiFi 6 Router (software EN_V1.0.0_r12_110933, hardware 1.0) devices. Certain /cgi-bin/luci/admin endpoints are vulnerable to command injection. Attackers can exploit this by sending crafted payloads through parameters intended for the ping utility, enabling arbitrary command execution with root-level permissions on the device. |
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root
This issue affects all Iocharger AC EV charger models on a firmware version before 25010801.
Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete
files and services.
CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). |
| Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user.
This issue affects Iocharger firmware for AC models before version 24120701.
Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload.
Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H). A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y). |