| A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V2.9.2), SIMATIC S7-1500 Software Controller (All versions < V21.9), SIMATIC S7-PLCSIM Advanced (All versions < V4.0), SINUMERIK MC (All versions < V6.21), SINUMERIK ONE (All versions < V6.21). Affected products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication.
This could allow attackers to discover the private key of a CPU product family by an offline attack against a single CPU of the family. Attackers could then use this knowledge to extract confidential configuration data from projects that are protected by that key or to perform attacks against legacy PG/PC and HMI communication. |
| Affected devices store the CLI user passwords encrypted in flash memory. Attackers with physical access to the device could retrieve the file and decrypt the CLI user passwords. |
| The EjbObjectInputStream class in Apache TomEE before 1.7.4 and 7.x before 7.0.0-M3 allows remote attackers to execute arbitrary code via a crafted serialized object. |
| Argument injection vulnerability in devscripts before 2.15.7 allows remote attackers to write to arbitrary files via a crafted symlink and crafted filename. |
| A design flaw in authentication in Synology Photo Station 6.0-2528 through 6.7.1-3419 allows local users to obtain credentials via cmdline. Synology Photo Station employs the synophoto_dsm_user program to authenticate username and password by "synophoto_dsm_user --auth USERNAME PASSWORD", and local users are able to obtain credentials by sniffing "/proc/*/cmdline". |
| IBM Kenexa LMS on Cloud 13.1 and 13.2 - 13.2.4 stores potentially sensitive information in in log files that could be read by an authenticated user. |
| An issue was discovered in Moxa MiiNePort E1 versions prior to 1.8, E2 versions prior to 1.4, and E3 versions prior to 1.1. An attacker may be able to brute force an active session cookie to be able to download configuration files. |
| Unspecified tests in Lynis before 2.5.0 allow local users to write to arbitrary files or possibly gain privileges via a symlink attack on a temporary file. |
| Apache Tika before 1.14 allows Java code execution for serialized objects embedded in MATLAB files. The issue exists because Tika invokes JMatIO to do native deserialization. |
| The Hotspot component in OpenJDK8 as packaged in Red Hat Enterprise Linux 6 and 7 allows local users to write to arbitrary files via a symlink attack. |
| The Reporting feature in X-Pack in versions prior to 5.5.2 and standalone Reporting plugin versions versions prior to 2.4.6 had an impersonation vulnerability. A user with the reporting_user role could execute a report with the permissions of another reporting user, possibly gaining access to sensitive data. |
| Prior to Logstash version 5.0.1, Elasticsearch Output plugin when updating connections after sniffing, would log to file HTTP basic auth credentials. |
| The klsi_105_get_line_state function in drivers/usb/serial/kl5kusb105.c in the Linux kernel before 4.9.5 places uninitialized heap-memory contents into a log entry upon a failure to read the line status, which allows local users to obtain sensitive information by reading the log. |
| mktexlsr revision 36855, and before revision 36626 as packaged in texlive allows local users to write to arbitrary files via a symlink attack. NOTE: this vulnerability exists due to the reversion of a fix of CVE-2015-5700. |
| A vulnerability in Swagger-Parser's (version <= 1.0.30) yaml parsing functionality results in arbitrary code being executed when a maliciously crafted yaml Open-API specification is parsed. This in particular, affects the 'generate' and 'validate' command in swagger-codegen (<= 2.2.2) and can lead to arbitrary code being executed when these commands are used on a well-crafted yaml specification. |
| IBM Websphere MQ JMS 7.0.1, 7.1, 7.5, 8.0, and 9.0 client provides classes that deserialize objects from untrusted sources which could allow a malicious user to execute arbitrary Java code by adding vulnerable classes to the classpath. IBM Reference #: 1983457. |
| Insufficient protection of password storage in system firmware for Intel NUC7i3BNK, NUC7i3BNH, NUC7i5BNK, NUC7i5BNH, NUC7i7BNH versions BN0049 and below allows local attackers to bypass Administrator and User passwords via access to password storage. |
| An Insufficiently Protected Credentials issue was discovered in Schneider Electric Modicon PLCs Modicon M241, all firmware versions, and Modicon M251, all firmware versions. Log-in credentials are sent over the network with Base64 encoding leaving them susceptible to sniffing. Sniffed credentials could then be used to log into the web application. |
| An issue was discovered in the node-serialize package 0.0.4 for Node.js. Untrusted data passed into the unserialize() function can be exploited to achieve arbitrary code execution by passing a JavaScript Object with an Immediately Invoked Function Expression (IIFE). |
| An issue was discovered in SMA Solar Technology products. All inverters have a very weak password policy for the user and installer password. No complexity requirements or length requirements are set. Also, strong passwords are impossible due to a maximum of 12 characters and a limited set of characters. NOTE: the vendor reports that the 12-character limit provides "a very high security standard." Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected |