Export limit exceeded: 421429 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (24298 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-34044 | 2026-04-15 | N/A | ||
| A remote command injection vulnerability exists in the confirm.php interface of the WIFISKY 7-layer Flow Control Router via a specially-crafted HTTP GET request to the t parameter. Insufficient input validation allows unauthenticated attackers to execute arbitrary OS commands. Exploitation evidence was observed by the Shadowserver Foundation on 2025-01-25 UTC. | ||||
| CVE-2024-0074 | 1 Nvidia | 1 Gpu Display Driver | 2026-04-15 | 7.1 High |
| NVIDIA GPU Display Driver for Linux contains a vulnerability where an attacker may access a memory location after the end of the buffer. A successful exploit of this vulnerability may lead to denial of service and data tampering. | ||||
| CVE-2025-34149 | 1 Shenzhen Aitemi | 2 M300, M300 Wifi Repeater | 2026-04-15 | N/A |
| A command injection vulnerability affects the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) during WPA2 configuration. The 'key' parameter is interpreted directly by the system shell, enabling attackers to execute arbitrary commands as root. Exploitation requires no authentication and can be triggered during wireless setup. | ||||
| CVE-2025-34150 | 1 Shenzhen Aitemi | 2 M300, M300 Wifi Repeater | 2026-04-15 | N/A |
| The PPPoE configuration interface of the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) is vulnerable to command injection via the 'user' parameter. Input is processed unsafely during network setup, allowing attackers to execute arbitrary system commands with root privileges. | ||||
| CVE-2025-34151 | 1 Shenzhen Aitemi | 2 M300, M300 Wifi Repeater | 2026-04-15 | N/A |
| A command injection vulnerability exists in the 'passwd' parameter of the PPPoE setup process on the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02). The input is passed directly to system-level commands without sanitation, enabling unauthenticated attackers to achieve root-level code execution. | ||||
| CVE-2024-28750 | 1 Ifm | 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware | 2026-04-15 | 7.2 High |
| A remote attacker with high privileges may use a deleting file function to inject OS commands. | ||||
| CVE-2024-28749 | 1 Ifm | 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware | 2026-04-15 | 7.2 High |
| A remote attacker with high privileges may use a writing file function to inject OS commands. | ||||
| CVE-2024-1848 | 2026-04-15 | 7.8 High | ||
| Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file. | ||||
| CVE-2025-34152 | 1 Shenzhen Aitemi | 2 M300, M300 Wifi Repeater | 2026-04-15 | N/A |
| An unauthenticated OS command injection vulnerability exists in the Shenzhen Aitemi M300 Wi-Fi Repeater (hardware model MT02) via the 'time' parameter of the '/protocol.csp?' endpoint. The input is processed by the internal date '-s' command without rebooting or disrupting HTTP service. Unlike other injection points, this vector allows remote compromise without triggering visible configuration changes. | ||||
| CVE-2024-28748 | 1 Ifm | 2 Smart Plc Ac14xx Firmware, Smart Plc Ac4xxs Firmware | 2026-04-15 | 7.2 High |
| A remote attacker with high privileges may use a reading file function to inject OS commands. | ||||
| CVE-2024-20295 | 1 Cisco | 1 Integrated Management Controller | 2026-04-15 | 8.8 High |
| A vulnerability in the CLI of the Cisco Integrated Management Controller (IMC) could allow an authenticated, local attacker to perform command injection attacks on the underlying operating system and elevate privileges to root. To exploit this vulnerability, the attacker must have read-only or higher privileges on an affected device. This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by submitting a crafted CLI command. A successful exploit could allow the attacker to elevate privileges to root. | ||||
| CVE-2025-24528 | 2 Mit, Redhat | 5 Kerberos 5, Discovery, Enterprise Linux and 2 more | 2026-04-15 | 7.1 High |
| In MIT Kerberos 5 (aka krb5) before 1.22 (with incremental propagation), there is an integer overflow for a large update size to resize() in kdb_log.c. An authenticated attacker can cause an out-of-bounds write and kadmind daemon crash. | ||||
| CVE-2023-7311 | 1 Bytevalue | 1 Flow Control Router | 2026-04-15 | N/A |
| BYTEVALUE Intelligent Flow Control Router contains a command injection vulnerability via the /goform/webRead/open endpoint. The `path` parameter is not properly validated and is echoed into a shell context, allowing an attacker to inject and execute arbitrary shell commands on the device. Successful exploitation can lead to writing backdoors, privilege escalation on the host, and full compromise of the router and its management functions. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign. | ||||
| CVE-2024-43651 | 2026-04-15 | N/A | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC models before version 241207101 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network connection serving the web interface is vulnerable (AV:N) and there are no additional measures to circumvent (AC:L) nor does the attack require special conditions to be present (AT:N). The attack requires authentication, but the level does not matter (PR:L), nor is user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H) and a compromised device can be used to potentially "pivot" into a network that should nopt be reachable (SC:L/SI:L/SA:H). Because this is an EV charger handing significant power, there is a potential safety impact (S:P). THe attack can be autometed (AU:Y). | ||||
| CVE-2023-53158 | 1 Gitoxidelabs | 1 Gix-transport | 2026-04-15 | 4.1 Medium |
| The gix-transport crate before 0.36.1 for Rust allows command execution via the "gix clone 'ssh://-oProxyCommand=open$IFS" substring. NOTE: this was discovered before CVE-2024-32884, a similar vulnerability (involving a username field) that is more difficult to exploit. | ||||
| CVE-2024-43653 | 2026-04-15 | 8.8 High | ||
| Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y). | ||||
| CVE-2025-12051 | 1 Insyde | 1 Insydeh2o | 2026-04-15 | 7.8 High |
| The drivers in the tool packages use RTL_QUERY_REGISTRY_DIRECT flag to read a registry value to which an untrusted user-mode application may be able to cause a buffer overflow. | ||||
| CVE-2023-47105 | 1 Chaosblade | 1 Chaosblade | 2026-04-15 | 8.6 High |
| exec.CommandContext in Chaosblade 0.3 through 1.7.3, when server mode is used, allows OS command execution via the cmd parameter without authentication. | ||||
| CVE-2025-4230 | 1 Palo Alto Networks | 1 Pan-os | 2026-04-15 | N/A |
| A command injection vulnerability in Palo Alto Networks PAN-OS® software enables an authenticated administrator to bypass system restrictions and run arbitrary commands as a root user. To be able to exploit this issue, the user must have access to the PAN-OS CLI. The security risk posed by this issue is significantly minimized when CLI access is restricted to a limited group of administrators. Cloud NGFW and Prisma® Access are not affected by this vulnerability. | ||||
| CVE-2024-39840 | 1 Factorio | 1 Factorio | 2026-04-15 | 8.8 High |
| Factorio before 1.1.101 allows a crafted server to execute arbitrary code on clients via a custom map that leverages the ability of certain Lua base module functions to execute bytecode and generate fake objects. | ||||