Search Results (24299 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-1655 2026-04-15 8.8 High
Certain ASUS WiFi routers models has an OS Command Injection vulnerability, allowing an authenticated remote attacker to execute arbitrary system commands by sending a specially crafted request.
CVE-2024-32639 1 Siemens 1 Tecnomatix Plant Simulation 2026-04-15 7.8 High
A vulnerability has been identified in Tecnomatix Plant Simulation V2302 (All versions < V2302.0011). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted MODEL file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-22974)
CVE-2024-32672 1 Samsung Open Source 1 Escargot 2026-04-15 5.3 Medium
A Segmentation Fault issue discovered in Samsung Open Source Escargot JavaScript engine allows remote attackers to cause a denial of service via crafted input. This issue affects Escargot: 4.0.0.
CVE-2024-34013 1 Acronis 1 True Image 2026-04-15 N/A
Local privilege escalation due to OS command injection vulnerability. The following products are affected: Acronis True Image (macOS) before build 41396, Acronis True Image OEM (macOS) before build 42571.
CVE-2025-30076 1 Koha 1 Koha 2026-04-15 7.7 High
Koha before 24.11.02 allows admins to execute arbitrary commands via shell metacharacters in the tools/scheduler.pl report parameter.
CVE-2025-67738 1 Webmin 1 Webmin 2026-04-15 8.5 High
squid/cachemgr.cgi in Webmin before 2.600 does not properly quote arguments. This is relevant if Webmin's Squid module and its Cache Manager feature are available, and an untrusted party is able to authenticate to Webmin and has certain Cache Manager permissions (the "cms" security option).
CVE-2024-38533 1 Matter-labs 1 Era-compiler-vyper 2026-04-15 6.5 Medium
ZKsync Era is a layer 2 rollup that uses zero-knowledge proofs to scale Ethereum. There is possible invalid stack access due to the addresses used to access the stack not properly being converted to cells. This issue has been patched in version 1.5.0.
CVE-2024-40641 1 Projectdiscovery 1 Nuclei 2026-04-15 7.4 High
Nuclei is a fast and customizable vulnerability scanner based on simple YAML based DSL. In affected versions it a way to execute code template without -code option and signature has been discovered. Some web applications inherit from Nuclei and allow users to edit and execute workflow files. In this case, users can execute arbitrary commands. (Although, as far as I know, most web applications use -t to execute). This issue has been addressed in version 3.3.0. Users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2025-54430 1 Dedupeio 1 Dedupe 2026-04-15 9.1 Critical
dedupe is a python library that uses machine learning to perform fuzzy matching, deduplication and entity resolution quickly on structured data. Before commit 3f61e79, a critical severity vulnerability has been identified within the .github/workflows/benchmark-bot.yml workflow, where a issue_comment can be triggered using the @benchmark body. This workflow is susceptible to exploitation as it checkout the ${{ github.event.issue.number }}, which correspond to the branch of the PR manipulated by potentially malicious actors, and where untrusted code may be executed. Running untrusted code may lead to the exfiltration of GITHUB_TOKEN, which in this workflow has write permissions on most of the scopes - in particular the contents one - and could lead to potential repository takeover. This is fixed by commit 3f61e79.
CVE-2024-41928 1 Freebsd 1 Freebsd 2026-04-15 8.4 High
Malicious software running in a guest VM can exploit the buffer overflow to achieve code execution on the host in the bhyve userspace process, which typically runs as root. Note that bhyve runs in a Capsicum sandbox, so malicious code is constrained by the capabilities available to the bhyve process.
CVE-2024-41956 1 Charmbracelet 1 Soft-serve 2026-04-15 8.1 High
Soft Serve is a self-hostable Git server for the command line. Prior to 0.7.5, it is possible for a user who can commit files to a repository hosted by Soft Serve to execute arbitrary code via environment manipulation and Git. The issue is that Soft Serve passes all environment variables given by the client to git subprocesses. This includes environment variables that control program execution, such as LD_PRELOAD. This vulnerability is fixed in 0.7.5.
CVE-2024-41992 1 Wi-fi-test Suite 1 Wi-fi-test Suite 2026-04-15 8.8 High
Wi-Fi Alliance wfa_dut (in Wi-Fi Test Suite) through 9.0.0 allows OS command injection via 802.11x frames because the system() library function is used. For example, on Arcadyan FMIMG51AX000J devices, this leads to wfaTGSendPing remote code execution as root via traffic to TCP port 8000 or 8080 on a LAN interface. On other devices, this may be exploitable over a WAN interface.
CVE-2024-42029 1 Xdg 1 Desktop Portal Hyperland 2026-04-15 6.3 Medium
xdg-desktop-portal-hyprland (aka an XDG Desktop Portal backend for Hyprland) before 1.3.3 allows OS command execution, e.g., because single quotes are not used when sending a list of app IDs and titles via the environment.
CVE-2025-34160 1 Aishu 1 Anyshare Cloud 2026-04-15 N/A
AnyShare contains a critical unauthenticated remote code execution vulnerability in the ServiceAgent API exposed on port 10250. The endpoint /api/ServiceAgent/start_service accepts user-supplied input via POST and fails to sanitize command-like payloads. An attacker can inject shell syntax that is interpreted by the backend, enabling arbitrary command execution. The vulnerability is presumed to affect builds released prior to August 2025 and is said to be remediated in newer versions of the product, though the exact affected range remains undefined. Exploitation evidence was first observed by the Shadowserver Foundation on 2025-07-11 UTC.
CVE-2025-20061 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with email information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2021-46686 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in acmailer CGI ver.4.0.3 and earlier and acmailer DB ver.1.1.5 and earlier. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker.
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-9977 1 Mitrastar 1 Gpt-2541gnac 2026-04-15 4.7 Medium
A vulnerability, which was classified as critical, was found in MitraStar GPT-2541GNAC BR_g5.6_1.11(WVK.0)b26. Affected is an unknown function of the file /cgi-bin/settings-firewall.cgi of the component Firewall Settings Page. The manipulation of the argument SrcInterface leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. We tried to contact the vendor early about the disclosure but the official mail address was not working properly.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).