| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Improper Validation of Specified Type of Input vulnerability in ABB FLXEON.A remote code execution is possible due to an improper input validation.
This issue affects FLXEON: through 9.3.5. |
| Improper Check for Unusual or Exceptional Conditions vulnerability in ABB WebPro SNMP Card PowerValue, ABB WebPro SNMP Card PowerValue UL.This issue affects WebPro SNMP Card PowerValue: through 1.1.8.K; WebPro SNMP Card PowerValue UL: through 1.1.8.K. |
| Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ABB CoreSense™ HM, ABB CoreSense™ M10.This issue affects CoreSense™ HM: through 2.3.1; CoreSense™ M10: through 1.4.1.12. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |
| Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. |
| Predictable filename vulnerabilities in ASPECT may expose sensitive information to a potential attacker if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| SQL injection vulnerabilities in ASPECT allow unintended access and manipulation of database repositories if session administrator credentials become compromised.
This issue affects ASPECT-Enterprise: through 3.08.03; NEXUS Series: through 3.08.03; MATRIX Series: through 3.08.03. |
| Windows permissions for ASPECT configuration toolsets are not fully secured allow-ing exposure of configuration informationThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Predictable filename vulnerabilities in ASPECT may expose sensitive information to a potential attacker if administrator credentials become compromisedThis issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in ABB EIBPORT V3 KNX, ABB EIBPORT V3 KNX GSM.This issue affects EIBPORT V3 KNX: before 3.9.2; EIBPORT V3 KNX GSM: before 3.9.2. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| Due to an issue in configuration, code that was intended for debugging purposes was included in the market release of the ASPECT FW allowing an attacker to bypass authentication. This vulnerability may allow an attacker to change the system time, access files, and make function calls without prior authentication. This issue affects all versions of ASPECT prior to 3.08.04-s01 |
| DLL's are not digitally signed when loaded in ASPECT's configuration toolset exposing the application to binary planting during device commissioning.This issue affects ASPECT-Enterprise: through 3.*; NEXUS Series: through 3.*; MATRIX Series: through 3.*. |
| Authentication bypass by capture-replay vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Missing authentication for critical function vulnerability in ABB AWIN GW100 rev.2, ABB AWIN GW120.This issue affects AWIN GW100 rev.2: 2.0-0, 2.0-1; AWIN GW120: 1.2-0, 1.2-1. |
| Improper Input Validation vulnerability in ABB 800xA Base.
An attacker who successfully exploited this
vulnerability could cause services to crash by sending specifically crafted messages.
This issue affects 800xA Base: from 6.0.0 through 6.1.1-2. |
| Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured. |
| An attacker could exploit the vulnerability by
injecting garbage data or specially crafted data. Depending on the data injected each process might be
affected differently. The process could crash or cause communication issues on the affected node, effectively causing a denial-of-service attack. The attacker could tamper with the data transmitted, causing
the product to store wrong information or act on wrong data or display wrong information.
This issue affects Advant MOD 300 AdvaBuild: from 3.0 through 3.7 SP2.
For an attack to be successful, the attacker must have local access to a node in the system and be able to
start a specially crafted application that disrupts the communication.
An attacker who successfully exploited the vulnerability would be able to manipulate the data in such
way as allowing reads and writes to the controllers or cause Windows processes in 800xA for MOD 300
and AdvaBuild to crash. |