Search Results (16528 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-4044 2 Lexmark, Microsoft 2 Universal Print Driver, Windows 2026-04-15 8.2 High
Improper Restriction of XML External Entity Reference in various Lexmark printer drivers for Windows allows attacker to disclose sensitive information to an arbitrary URL.
CVE-2020-37192 2 Password-solutions, Top Password Software 2 Office Password Recovery, Msn Password Recovery 2026-04-15 6.2 Medium
MSN Password Recovery 1.30 contains an XML external entity injection vulnerability that allows attackers to read local system files through crafted XML input. Attackers can exploit the 'Favorites' tab by injecting a malicious XML file that references external entities to retrieve sensitive system configuration information.
CVE-2024-54731 2026-04-15 4 Medium
cpdf through 2.8 allows stack consumption via a crafted PDF document.
CVE-2025-46826 2026-04-15 N/A
insa-auth is an authentication server for INSA Rouen. A minor issue allowed third-party websites to access the server's secondary authentication bridge, potentially revealing basic student information (name and number). However, the issue posed minimal risk, was never exploited, and had limited impact. A fix was implemented promptly on May 3, 2025.
CVE-2023-32189 2026-04-15 5.9 Medium
Insecure handling of ssh keys used to bootstrap clients allows local attackers to potentially gain access to the keys
CVE-2025-46386 2026-04-15 8.8 High
CWE-639 Authorization Bypass Through User-Controlled Key
CVE-2025-41251 1 Vmware 3 Cloud Foundation, Nsx, Nsx-t 2026-04-15 8.1 High
VMware NSX contains a weak password recovery mechanism vulnerability. An unauthenticated malicious actor may exploit this to enumerate valid usernames, potentially enabling brute-force attacks. Impact: Username enumeration → credential brute force risk. Attack Vector: Remote, unauthenticated. Severity: Important. CVSSv3: 8.1 (High). Acknowledgments: Reported by the National Security Agency. Affected Products:VMware NSX 9.x.x.x, 4.2.x, 4.1.x, 4.0.x NSX-T 3.x VMware Cloud Foundation (with NSX) 5.x, 4.5.x Fixed Versions: NSX 9.0.1.0; 4.2.2.2/4.2.3.1 http://4.2.2.2/4.2.3.1 ; 4.1.2.7; NSX-T 3.2.4.3; CCF async patch (KB88287). Workarounds: None.
CVE-2025-61766 1 Mediawiki 1 Mediawiki 2026-04-15 6.5 Medium
Bucket is a MediaWiki extension to store and retrieve structured data on articles. Prior to version 1.0.0, infinite recursion can occur if a user queries a bucket using the `!=` comparator. This will result in PHP's call stack limit exceeding, and/or increased memory consumption, potentially leading to a denial of service. Version 1.0.0 contains a patch for the issue.
CVE-2024-42185 2026-04-15 2.5 Low
BigFix Patch Download Plug-ins are affected by an insecure package which is susceptible to XML injection attacks. This allows an attacker to exploit this vulnerability by injecting malicious XML content, which can lead to various issues including denial of service and unauthorized access.
CVE-2024-12306 1 Unifiedtransform 1 Unifiedtransform 2026-04-15 4.3 Medium
Multiple access control vulnerabilities in Unifiedtransform version 2.0 and potentially earlier versions allow unauthorized access to personal information of students and teachers. The vulnerabilities include both function-level access control issues in list viewing endpoints and object-level access control issues in profile viewing endpoints. A malicious student user can access personal information of other students and teachers through these vulnerabilities. At the time of publication of the CVE no patch is available.
CVE-2024-43803 1 Redhat 1 Openshift 2026-04-15 4.9 Medium
The Bare Metal Operator (BMO) implements a Kubernetes API for managing bare metal hosts in Metal3. The `BareMetalHost` (BMH) CRD allows the `userData`, `metaData`, and `networkData` for the provisioned host to be specified as links to Kubernetes Secrets. There are fields for both the `Name` and `Namespace` of the Secret, meaning that versions of the baremetal-operator prior to 0.8.0, 0.6.2, and 0.5.2 will read a `Secret` from any namespace. A user with access to create or edit a `BareMetalHost` can thus exfiltrate a `Secret` from another namespace by using it as e.g. the `userData` for provisioning some host (note that this need not be a real host, it could be a VM somewhere). BMO will only read a key with the name `value` (or `userData`, `metaData`, or `networkData`), so that limits the exposure somewhat. `value` is probably a pretty common key though. Secrets used by _other_ `BareMetalHost`s in different namespaces are always vulnerable. It is probably relatively unusual for anyone other than cluster administrators to have RBAC access to create/edit a `BareMetalHost`. This vulnerability is only meaningful, if the cluster has users other than administrators and users' privileges are limited to their respective namespaces. The patch prevents BMO from accepting links to Secrets from other namespaces as BMH input. Any BMH configuration is only read from the same namespace only. The problem is patched in BMO releases v0.7.0, v0.6.2 and v0.5.2 and users should upgrade to those versions. Prior upgrading, duplicate the BMC Secrets to the namespace where the corresponding BMH is. After upgrade, remove the old Secrets. As a workaround, an operator can configure BMO RBAC to be namespace scoped for Secrets, instead of cluster scoped, to prevent BMO from accessing Secrets from other namespaces.
CVE-2025-42605 2026-04-15 N/A
This vulnerability exists in Meon Bidding Solutions due to improper authorization controls on certain API endpoints for the initiation, modification, or cancellation operations. An authenticated remote attacker could exploit this vulnerability by manipulating parameter in the API request body to gain unauthorized access to other user accounts. Successful exploitation of this vulnerability could allow remote attacker to perform authorized manipulation of data associated with other user accounts.
CVE-2024-53007 2026-04-15 6.4 Medium
Bentley Systems ProjectWise Integration Server before 10.00.03.288 allows unintended SQL query execution by an authenticated user via an API call.
CVE-2025-55060 2026-04-15 6.1 Medium
CWE-601 URL Redirection to Untrusted Site ('Open Redirect')
CVE-2024-10497 2026-04-15 8.8 High
CWE-639: Authorization Bypass Through User-Controlled Key vulnerability exists that could allow an authorized attacker to modify values outside those defined by their privileges (Elevation of Privileges) when the attacker sends modified HTTPS requests to the device.
CVE-2025-4838 2026-04-15 4.3 Medium
A vulnerability, which was classified as problematic, was found in kanwangzjm Funiture up to 71ca0fb0658b3d839d9e049ac36429207f05329b. Affected is the function doPost of the file /funiture-master/src/main/java/com/app/mvc/acl/servlet/LoginServlet.java of the component Login. The manipulation of the argument ret leads to open redirect. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available.
CVE-2025-12854 1 Newbee-mall Project 1 Newbee-mall 2026-04-15 3.7 Low
A vulnerability was identified in newbee-mall-plus up to 2.4.1. This vulnerability affects the function executeSeckill of the file /seckillExecution/. The manipulation of the argument userid leads to authorization bypass. It is possible to initiate the attack remotely. The attack is considered to have high complexity. It is stated that the exploitability is difficult. The exploit is publicly available and might be used.
CVE-2023-35123 2026-04-15 4.3 Medium
Uncaught exception in OpenBMC Firmware for some Intel(R) Server Platforms before versions egs-1.14-0, bhs-0.27 may allow an authenticated user to potentially enable denial of service via network access.
CVE-2024-45032 1 Siemens 2 Industrial Edge Management Pro, Industrial Edge Management Virtual 2026-04-15 10 Critical
A vulnerability has been identified in Industrial Edge Management Pro (All versions < V1.9.5), Industrial Edge Management Virtual (All versions < V2.3.1-1). Affected components do not properly validate the device tokens. This could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system.
CVE-2025-61197 1 Orban 3 Optimod 5750, Optimod 5950, Optimod Trio 2026-04-15 8.9 High
An issue in Orban Optimod 5950, Optimod 5950HD, Optimod 5750, Optimod 5750HD, Optimod Trio Optimod version 1.0.0.33 - System version 2.5.26 allows a remote attacker to escalate privileges via the application stores user privilege/role information in client-side browser storage