| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Invalid file validation on the upload feature in GROWI versions v4.2.2 allows a remote attacker with administrative privilege to overwrite the files on the server, which may lead to arbitrary code execution. |
| Improper access control vulnerability in GROWI versions v4.2.2 and earlier allows a remote unauthenticated attacker to read the user's personal information and/or server's internal information via unspecified vectors. |
| Missing authentication for critical function in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an attacker to alter the setting information without the access privileges via unspecified vectors. |
| Directory traversal vulnerability in SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows authenticated attackers to delete arbitrary files and/or directories on the server via unspecified vectors. |
| SolarView Compact SV-CPT-MC310 prior to Ver.6.5 allows an authenticated attacker to upload arbitrary files via unspecified vectors. If the file is PHP script, an attacker may execute arbitrary code. |
| FileZen (V3.0.0 to V4.2.7 and V5.0.0 to V5.0.2) allows a remote attacker with administrator rights to execute arbitrary OS commands via unspecified vectors. |
| Cross-site request forgery (CSRF) vulnerability in Name Directory 1.17.4 and earlier allows remote attackers to hijack the authentication of administrators via unspecified vectors. |
| Improper access control vulnerability in ELECOM LD-PS/U1 allows remote attackers to change the administrative password of the affected device by processing a specially crafted request. |
| Cross-site request forgery (CSRF) vulnerability in Aterm WG2600HP firmware Ver1.0.2 and earlier, and Aterm WG2600HP2 firmware Ver1.0.2 and earlier allows remote attackers to hijack the authentication of administrators via unspecified vectors. |
| Untrusted search path vulnerability in the installer of SKYSEA Client View Ver.1.020.05b to Ver.16.001.01g allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. |
| Improper initialization vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.16 and prior, FX3U-ENET-L Firmware version 1.16 and prior and FX3U-ENET-P502 Firmware version 1.16 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product by sending specially crafted packets. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery. |
| Lack of administrator control over security vulnerability in MELSEC-F series FX3U-ENET Firmware version 1.14 and prior, FX3U-ENET-L Firmware version 1.14 and prior and FX3U-ENET-P502 Firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition in communication function of the product or other unspecified effects by sending specially crafted packets to an unnecessary opening of TCP port. Control by MELSEC-F series PLC is not affected by this vulnerability, but system reset is required for recovery. |
| Improper Input Validation vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU, MELSEC iQ-R Series R04/08/16/32/120(EN)CPU, MELSEC iQ-R Series R08/16/32/120SFCPU, MELSEC iQ-R Series R08/16/32/120PCPU, MELSEC iQ-R Series R08/16/32/120PSFCPU, MELSEC iQ-R Series R16/32/64MTCPU, MELSEC iQ-R Series R12CCPU-V, MELSEC Q Series Q03UDECPU, MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU, MELSEC Q Series Q03/04/06/13/26UDVCPU, MELSEC Q Series Q04/06/13/26UDPVCPU, MELSEC Q Series Q12DCCPU-V, MELSEC Q Series Q24DHCCPU-V(G), MELSEC Q Series Q24/26DHCCPU-LS, MELSEC Q Series MR-MQ100, MELSEC Q Series Q172/173DCPU-S1, MELSEC Q Series Q172/173DSCPU, MELSEC Q Series Q170MCPU, MELSEC Q Series Q170MSCPU(-S1), MELSEC L Series L02/06/26CPU(-P), MELSEC L Series L26CPU-(P)BT and MELIPC Series MI5122-VW allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery. |
| Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU, MELSEC iQ-R Series R04/08/16/32/120(EN)CPU, MELSEC iQ-R Series R08/16/32/120SFCPU, MELSEC iQ-R Series R08/16/32/120PCPU, MELSEC iQ-R Series R08/16/32/120PSFCPU, MELSEC iQ-R Series R16/32/64MTCPU, MELSEC iQ-R Series R12CCPU-V, MELSEC Q Series Q03UDECPU, MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU, MELSEC Q Series Q03/04/06/13/26UDVCPU, MELSEC Q Series Q04/06/13/26UDPVCPU, MELSEC Q Series Q12DCCPU-V, MELSEC Q Series Q24DHCCPU-V(G), MELSEC Q Series Q24/26DHCCPU-LS, MELSEC Q Series MR-MQ100, MELSEC Q Series Q172/173DCPU-S1, MELSEC Q Series Q172/173DSCPU, MELSEC Q Series Q170MCPU, MELSEC Q Series Q170MSCPU(-S1), MELSEC L Series L02/06/26CPU(-P), MELSEC L Series L26CPU-(P)BT and MELIPC Series MI5122-VW allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery. |
| Uncontrolled Resource Consumption vulnerability in Mitsubishi Electric MELSEC iQ-R Series R00/01/02CPU, MELSEC iQ-R Series R04/08/16/32/120(EN)CPU, MELSEC iQ-R Series R08/16/32/120SFCPU, MELSEC iQ-R Series R08/16/32/120PCPU, MELSEC iQ-R Series R08/16/32/120PSFCPU, MELSEC iQ-R Series R16/32/64MTCPU, MELSEC iQ-R Series R12CCPU-V, MELSEC Q Series Q03UDECPU, MELSEC Q Series Q04/06/10/13/20/26/50/100UDEHCPU, MELSEC Q Series Q03/04/06/13/26UDVCPU, MELSEC Q Series Q04/06/13/26UDPVCPU, MELSEC Q Series Q12DCCPU-V, MELSEC Q Series Q24DHCCPU-V(G), MELSEC Q Series Q24/26DHCCPU-LS, MELSEC Q Series MR-MQ100, MELSEC Q Series Q172/173DCPU-S1, MELSEC Q Series Q172/173DSCPU, MELSEC Q Series Q170MCPU, MELSEC Q Series Q170MSCPU(-S1), MELSEC L Series L02/06/26CPU(-P), MELSEC L Series L26CPU-(P)BT and MELIPC Series MI5122-VW allows a remote unauthenticated attacker to cause a denial-of-service (DoS) condition by sending specially crafted packets. System reset is required for recovery. |
| Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file. |
| Improper input validation vulnerability in GOT2000 series GT27 model all versions, GOT2000 series GT25 model all versions, GOT2000 series GT23 model all versions, GOT2000 series GT21 model all versions, GOT SIMPLE series GS21 model all versions, and GT SoftGOT2000 all versions allows an remote unauthenticated attacker to write a value that exceeds the configured input range limit by sending a malicious packet to rewrite the device value. As a result, the system operation may be affected, such as malfunction. |
| NULL Pointer Dereference in MELSEC-F Series FX3U-ENET firmware version 1.14 and prior, FX3U-ENET-L firmware version 1.14 and prior and FX3U-ENET-P502 firmware version 1.14 and prior allows a remote unauthenticated attacker to cause a DoS condition in communication by sending specially crafted packets. Control by MELSEC-F series PLC is not affected and system reset is required for recovery. |
| Improper Restriction of XML External Entity Reference vulnerability in Mitsubishi Electric Air Conditioning System/Centralized Controllers (G-50A Ver.3.35 and prior, GB-50A Ver.3.35 and prior, GB-24A Ver.9.11 and prior, AG-150A-A Ver.3.20 and prior, AG-150A-J Ver.3.20 and prior, GB-50ADA-A Ver.3.20 and prior, GB-50ADA-J Ver.3.20 and prior, EB-50GU-A Ver 7.09 and prior, EB-50GU-J Ver 7.09 and prior, AE-200A Ver 7.93 and prior, AE-200E Ver 7.93 and prior, AE-50A Ver 7.93 and prior, AE-50E Ver 7.93 and prior, EW-50A Ver 7.93 and prior, EW-50E Ver 7.93 and prior, TE-200A Ver 7.93 and prior, TE-50A Ver 7.93 and prior, TW-50A Ver 7.93 and prior, CMS-RMD-J Ver.1.30 and prior), Air Conditioning System/Expansion Controllers (PAC-YG50ECA Ver.2.20 and prior) and Air Conditioning System/BM adapter(BAC-HD150 Ver.2.21 and prior) allows a remote unauthenticated attacker to disclose some of data in the air conditioning system or cause a DoS condition by sending specially crafted packets. |
| Exposure of Sensitive Information to an Unauthorized Actor vulnerability in Mitsubishi Electric MELSEC iQ-R series Safety CPU modules R08/16/32/120SFCPU firmware versions "26" and prior and Mitsubishi Electric MELSEC iQ-R series SIL2 Process CPU modules R08/16/32/120PSFCPU firmware versions "11" and prior allows a remote unauthenticated attacker to acquire legitimate user names registered in the module via brute-force attack on user names. |