| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A local privilege escalation vulnerability exists in BlueStacks App Player. The BlueStacks App Player installer creates a registry key with weak permissions that allows users to execute arbitrary programs with SYSTEM privileges. |
| EMC Avamar Data Store (ADS) and Avamar Virtual Edition (AVE) versions 7.3.0 and 7.3.1 contain a vulnerability that may allow malicious administrators to compromise Avamar servers. |
| Huawei FusionServer rack servers RH2288 V3 with software before V100R003C00SPC603, RH2288H V3 with software before V100R003C00SPC503, XH628 V3 with software before V100R003C00SPC602, RH1288 V3 with software before V100R003C00SPC602, RH2288A V2 with software before V100R002C00SPC701, RH1288A V2 with software before V100R002C00SPC502, RH8100 V3 with software before V100R003C00SPC110, CH222 V3 with software before V100R001C00SPC161, CH220 V3 with software before V100R001C00SPC161, and CH121 V3 with software before V100R001C00SPC161 allow remote authenticated operators to change server information by leveraging failure to verify user permissions. |
| An unspecified server utility in NoMachine before 5.3.10 on Mac OS X and Linux allows authenticated users to gain privileges by gaining access to local files. |
| An incorrect permissions vulnerability in Juniper Networks Junos OS on vMX may allow local unprivileged users on a host system read access to vMX or vPFE images and obtain sensitive information contained in them such as private cryptographic keys. This issue was found during internal product security testing. Juniper SIRT is not aware of any malicious exploitation of this vulnerability. No other Juniper Networks products or platforms are affected by this issue. Affected releases are Juniper Networks Junos OS 15.1 prior to 15.1F5; 14.1 prior to 14.1R8 |
| Cybozu Office 9.0.0 to 10.4.0 allows remote authenticated attackers to execute unintended operations via the Project function. |
| The BIOS in Intel Compute Stick systems based on 6th Gen Intel Core processors prior to version CC047 may allow an attacker with physical access to the system to gain access to personal information. |
| With OxygenOS before 4.0.3, when a charger is connected to a powered-off OnePlus 3 or 3T device, the platform starts with adbd enabled. Therefore, a malicious charger or a physical attacker can open up, without authorization, an ADB session with the device, in order to further exploit other vulnerabilities and/or exfiltrate sensitive information. |
| The SecEmailComposer/EmailComposer application in the Samsung S6 Edge before the October 2015 MR uses weak permissions for the com.samsung.android.email.intent.action.QUICK_REPLY_BACKGROUND service action, which might allow remote attackers with knowledge of the local email address to obtain sensitive information via a crafted application that sends a crafted intent. |
| An issue was discovered in EMC ScaleIO versions before 2.0.1.1. Incorrect permissions on the SCINI driver may allow a low-privileged local attacker to modify the configuration and render the ScaleIO Data Client (SDC) server unavailable. |
| An issue was discovered in Logpoint 7.1 before 7.1.2. The daily executed cron file clean_secbi_old_logs is writable by all users and is executed as root, leading to privilege escalation. |
| Sourcecodester Human Resource Management System 1.0 is vulnerable to Insecure Permissions resulting in privilege escalation. |
| Insecure permission vulnerability in /hrm/leaverequest.php in SourceCodester Human Resource Management System 1.0 allow attackers to approve or reject leave ticket. |
| Sysmac Studio installs executables in a directory with poor permissions. This can allow a locally-authenticated attacker to overwrite files which will result in code execution with privileges of a different user. |
| Apiman 1.5.7 through 2.2.3.Final has insufficient checks for read permissions within the Apiman Manager REST API. The root cause of the issue is the Apiman project's accidental acceptance of a large contribution that was not fully compatible with the security model of Apiman versions before 3.0.0.Final. Because of this, 3.0.0.Final is not affected by the vulnerability. |
| Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. |
| Delta Electronics DIAEnergie (All versions prior to 1.8.02.004) is vulnerable to an incorrect default permission in the DIAEnergie application, which may allow an attacker to plant new files (such as DLLs) or replace existing executable files. |
| Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. |
| The security descriptor of Measuresoft ScadaPro Server version 6.7 has inconsistent permissions, which could allow a local user with limited privileges to modify the service binary path and start malicious commands with SYSTEM privileges. |
| An issue was discovered in Elspec G5 digital fault recorder versions 1.1.4.15 and before. The shadow file is world readable. |