Search Results (818 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-13905 1 Schneider-electric 2 Ecostruxure Process Expert, Ecostruxure Process Expert For Aveva System Platform 2026-04-15 N/A
CWE-276: Incorrect Default Permissions vulnerability exists that could cause privilege escalation through the reverse shell when one or more executable service binaries are modified in the installation folder by a local user with normal privilege upon service restart.
CVE-2025-8449 1 Schneider-electric 3 Ecostruxure Building Operation Enterprise Server, Ecostruxure Enterprise Server, Ecostruxure Workstation 2026-04-15 N/A
CWE-400: Uncontrolled Resource Consumption vulnerability exists that could cause a denial of service when an authenticated user sends a specially crafted request to a specific endpoint from within the BMS network.
CVE-2025-54926 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.2 High
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed.
CVE-2025-9997 1 Schneider-electric 1 Blmon 2026-04-15 N/A
CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could cause command injection in BLMon that is executed in the operating system console when in a SSH session.
CVE-2025-6625 1 Schneider-electric 12 Bmxngd0100, Bmxngd0100 Firmware, Bmxnoc0401 and 9 more 2026-04-15 7.5 High
CWE-20: Improper Input Validation vulnerability exists that could cause a Denial Of Service when specific crafted FTP command is sent to the device.
CVE-2025-54925 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 7.5 High
CWE-918: Server-Side Request Forgery (SSRF) vulnerability exists that could cause unauthorized access to sensitive data when an attacker configures the application to access a malicious url.
CVE-2025-54927 1 Schneider-electric 2 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation With Advanced Reports 2026-04-15 4.9 Medium
CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause unauthorized access to sensitive files when an authenticated attackers uses a crafted path input that is processed by the system.
CVE-2025-11739 1 Schneider-electric 3 Ecostruxure Power Monitoring Expert, Ecostruxure Power Operation, Ecostruxure Power Operation With Advanced Reporting And Dashboards 2026-03-11 7.8 High
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.
CVE-2025-13902 1 Schneider-electric 10 Modicon Controllers M241/m251, Modicon Controllers M258/lmc058, Modicon Lmc058 and 7 more 2026-03-11 5.4 Medium
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.
CVE-2025-13901 1 Schneider-electric 7 Modicon M241, Modicon M241/m251, Modicon M241 Firmware and 4 more 2026-03-11 5.3 Medium
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.
CVE-2025-13957 1 Schneider-electric 1 Struxureware Data Center Expert 2026-03-11 N/A
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default.
CVE-2025-13844 1 Schneider-electric 1 Ecostruxure Power Build - Rapsody 2026-03-03 5.3 Medium
CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the attacker into Rapsody.
CVE-2023-6407 2 Microsoft, Schneider-electric 6 Windows 10 1507, Windows 11 21h2, Windows Server 2016 and 3 more 2026-02-25 5.3 Medium
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker.
CVE-2018-1124 6 Canonical, Debian, Opensuse and 3 more 13 Ubuntu Linux, Debian Linux, Leap and 10 more 2025-12-18 7.8 High
procps-ng before version 3.3.15 is vulnerable to multiple integer overflows leading to a heap corruption in file2strvec function. This allows a privilege escalation for a local attacker who can create entries in procfs by starting processes, which could result in crashes or arbitrary code execution in proc utilities run by other users.
CVE-2018-1126 5 Canonical, Debian, Procps-ng Project and 2 more 13 Ubuntu Linux, Debian Linux, Procps-ng and 10 more 2025-12-17 N/A
procps-ng before version 3.3.15 is vulnerable to an incorrect integer size in proc/alloc.* leading to truncation/integer overflow issues. This flaw is related to CVE-2018-1124.
CVE-2014-5413 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 uses the MD5 algorithm for an X.509 certificate, which makes it easier for remote attackers to spoof servers via a cryptographic attack against this algorithm.
CVE-2014-5412 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allows remote attackers to read database records by leveraging access to the guest account.
CVE-2014-5411 2 Aveva, Schneider-electric 2 Clearscada, Scada Expert Clearscada 2025-11-04 N/A
Multiple cross-site scripting (XSS) vulnerabilities in Schneider Electric StruxureWare SCADA Expert ClearSCADA 2010 R3 through 2014 R1 allow remote authenticated users to inject arbitrary web script or HTML via unspecified vectors.
CVE-2014-5407 1 Schneider-electric 1 Vampset 2025-11-03 N/A
Multiple stack-based buffer overflows in Schneider Electric VAMPSET 2.2.136 and earlier allow local users to cause a denial of service (application halt) via a malformed (1) setting file or (2) disturbance recording file.
CVE-2018-7841 1 Schneider-electric 1 U.motion Builder 2025-11-03 9.8 Critical
A SQL Injection (CWE-89) vulnerability exists in U.motion Builder software version 1.3.4 which could cause unwanted code execution when an improper set of characters is entered.