| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Polkit authentication dis isabled by default and a race
condition in the Polkit authorization check in versions before v0.69.0 can
lead to the same issues as in CVE-2025-66005. |
| A Improper Access Control vulnerability in SUSE rancher allows a local user to impersonate other identities through SAML Authentication on first login.
This issue affects rancher: from 2.8.0 before 2.8.13, from 2.9.0 before 2.9.7, from 2.10.0 before 2.10.3. |
| conda-forge infrastructure holds common configurations and settings for key pieces of the conda-forge infrastructure.
Between 2025-02-10 and 2025-04-01, conda-forge infrastructure used the wrong token for Azure's cf-staging access. This bug meant that any feedstock maintainer could upload a package to the conda-forge channel, bypassing our feedstock-token + upload process. The security logs on anaconda.org were check for any packages that were not copied from the cf-staging to the conda-forge channel and none were found. |
| A vulnerability classified as critical was found in Xiongmai AHB7804R-MH-V2, AHB8004T-GL, AHB8008T-GL, AHB7004T-GS-V3, AHB7004T-MHV2, AHB8032F-LME and XM530_R80X30-PQ_8M. Affected by this vulnerability is an unknown functionality of the component Sofia Service. The manipulation with the input ff00000000000000000000000000f103250000007b202252657422203a203130302c202253657373696f6e494422203a202230783022207d0a leads to improper access controls. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-260605 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| PIX-LINK LV-WR22 RE3002-P1-01_V117.0 is vulnerable to Improper Access Control. The TELNET service is enabled with weak credentials for a root-level account, without the possibility of changing them. |
| pluginsGLPI's Database Inventory Plugin "manages" the Teclib' inventory agents in order to perform an inventory of the databases present on the workstation. In versions prior to 1.0.3, any authenticated user could send requests to agents. This issue has been patched in version 1.0.3. |
| OpenOrange Business Framework version 1.15.5 installs to a directory with overly permissive access control, allowing all authenticated users to write to the installation path. In combination with the application's behavior of loading DLLs from this location, this allows for DLL hijacking and may result in arbitrary code execution and privilege escalation. |
| Anti-Cheat Expert's Windows kernel module "ACE-BASE.sys" version 1.0.2202.6217 does not perform proper access control when handling system resources. This allows a local attacker to escalate privileges from regular user to System or PPL level. |
| Incorrect access control in Itel Electronics IP Stream v1.7.0.6 allows unauthorized attackers to execute arbitrary commands with Administrator privileges. |
| A vulnerability has been identified in SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices with role `user` is affected by incorrect authorization in SNMPv3 View configuration. This could allow an attacker to change the View Type of SNMPv3 Views. |
| A vulnerability in Cisco Catalyst Center Virtual Appliance could allow an authenticated, remote attacker to elevate privileges to Administrator on an affected system.
This vulnerability is due to insufficient validation of user-supplied input. An attacker could exploit this vulnerability by submitting a crafted HTTP request to an affected system. A successful exploit could allow the attacker to perform unauthorized modifications to the system, including creating new user accounts or elevating their own privileges on an affected system. To exploit this vulnerability, the attacker must have valid credentials for a user account with at least the role of Observer. |
| The Facebook Chat Plugin for WordPress is vulnerable to authorization bypass due to a missing capability check on the wp_ajax_update_options function in versions up to, and including, 1.5. This flaw makes it possible for low-level authenticated attackers to connect their own Facebook Messenger account to any site running the vulnerable plugin and engage in chats with site visitors on affected sites. |
| The Net::IPV4Addr module 0.10 for Perl does not properly consider extraneous zero characters in an IP address string, which (in some situations) allows attackers to bypass access control that is based on IP addresses. |
| An issue was discovered on certain Nuki Home Solutions devices. Some BLE commands, which should have been designed to be only called from privileged accounts, could also be called from unprivileged accounts. This demonstrates that no access controls were implemented for the different BLE commands across the different accounts. This affects Nuki Smart Lock 3.0 before 3.3.5 and Nuki Smart Lock 2.0 before 2.12.4. |
| Northern.tech Mender 3.3.x before 3.3.2 and 3.4.x before 3.4.0 has Incorrect Access Control and allows low-privileged users default read access to some sensitive device information. |
| Voltronic Power ViewPower through 1.04-21353 and PowerShield Netguard before 1.04-23292 allows a remote attacker to configure the system via an unspecified web interface. An unauthenticated remote attacker can make changes to the system including: changing the web interface admin password, view/change system configuration, enumerate connected UPS devices and shut down connected UPS devices. This extends to being able to configure operating system commands that should run if the system detects a connected UPS shutting down. |
| A vulnerability has been identified in Node.js version 20, affecting users of the experimental permission model when the --allow-fs-read flag is used with a non-* argument. This flaw arises from an inadequate permission model that fails to restrict file watching through the fs.watchFile API. As a result, malicious actors can monitor files that they do not have explicit read access to.
Please note that at the time this CVE was issued, the permission model is an experimental feature of Node.js. |
| fs.openAsBlob() can bypass the experimental permission model when using the file system read restriction with the `--allow-fs-read` flag in Node.js 20. This flaw arises from a missing check in the `fs.openAsBlob()` API.
Please note that at the time this CVE was issued, the permission model is an experimental feature of Node.js. |
| A vulnerability in Node.js version 20 allows for bypassing restrictions set by the --experimental-permission flag using the built-in inspector module (node:inspector).
By exploiting the Worker class's ability to create an "internal worker" with the kIsInternal Symbol, attackers can modify the isInternal value when an inspector is attached within the Worker constructor before initializing a new WorkerImpl. This vulnerability exclusively affects Node.js users employing the permission model mechanism.
Please note that at the time this CVE was issued, the permission model is an experimental feature of Node.js. |
| Various software builds for the following TCL 30Z and TCL A3X devices leak the ICCID to a system property that can be accessed by any local app on the device without any permissions or special privileges. Google restricted third-party apps from directly obtaining non-resettable device identifiers in Android 10 and higher, but in these instances they are leaked by a high-privilege process and can be obtained indirectly. The software build fingerprints for each confirmed vulnerable device are as follows: TCL 30Z (TCL/4188R/Jetta_ATT:12/SP1A.210812.016/LV8E:user/release-keys, TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU5P:user/release-keys, TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU61:user/release-keys, TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU66:user/release-keys, TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU68:user/release-keys, TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU6P:user/release-keys, and TCL/T602DL/Jetta_TF:12/SP1A.210812.016/vU6X:user/release-keys) and TCL A3X (TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vAAZ:user/release-keys, TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vAB3:user/release-keys, TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vAB7:user/release-keys, TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vABA:user/release-keys, TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vABM:user/release-keys, TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vABP:user/release-keys, and TCL/A600DL/Delhi_TF:11/RKQ1.201202.002/vABS:user/release-keys). This malicious app reads from the "persist.sys.tctPowerIccid" system property to indirectly obtain the ICCID. |