| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| WINSTAR WN572HP3 v230525 was discovered to contain a heap overflow via the CONTENT_LENGTH variable at /cgi-bin/upload.cgi. |
| Sharp NEC Projectors (NP-CB4500UL, NP-CB4500WL, NP-CB4700UL, NP-P525UL, NP-P525UL+, NP-P525ULG, NP-P525ULJL, NP-P525WL, NP-P525WL+, NP-P525WLG, NP-P525WLJL, NP-CG6500UL, NP-CG6500WL, NP-CG6700UL, NP-P605UL, NP-P605UL+, NP-P605ULG, NP-P605ULJL, NP-CA4120X, NP-CA4160W, NP-CA4160X, NP-CA4200U, NP-CA4200W, NP-CA4202W, NP-CA4260X, NP-CA4300X, NP-CA4355X, NP-CD2100U, NP-CD2120X, NP-CD2300X, NP-CR2100X, NP-CR2170W, NP-CR2170X, NP-CR2200U, NP-CR2200W, NP-CR2280X, NP-CR2310X, NP-CR2350X, NP-MC302XG, NP-MC332WG, NP-MC332WJL, NP-MC342XG, NP-MC372X, NP-MC372XG, NP-MC382W, NP-MC382WG, NP-MC422XG, NP-ME342UG, NP-ME372W, NP-ME372WG, NP-ME372WJL, NP-ME382U, NP-ME382UG, NP-ME382UJL, NP-ME402X, NP-ME402XG, NP-ME402XJL, NP-CB4500XL, NP-CG6400UL, NP-CG6400WL, NP-CG6500XL, NP-PE455UL, NP-PE455ULG, NP-PE455WL, NP-PE455WLG, NP-PE505XLG, NP-CB4600U, NP-CF6600U, NP-P474U, NP-P554U, NP-P554U+, NP-P554UG, NP-P554UJL, NP-CG6600UL, NP-P547UL, NP-P547ULG, NP-P547ULJL, NP-P607UL+, NP-P627UL, NP-P627UL+, NP-P627ULG, NP-P627ULJL, NP-PV710UL-B, NP-PV710UL-B1, NP-PV710UL-W, NP-PV710UL-W+, NP-PV710UL-W1, NP-PV730UL-BJL, NP-PV730UL-WJL, NP-PV800UL-B, NP-PV800UL-B+, NP-PV800UL-B1, NP-PV800UL-BJL, NP-PV800UL-W, NP-PV800UL-W+, NP-PV800UL-W1, NP-PV800UL-WJL, NP-CA4200X, NP-CA4265X, NP-CA4300U, NP-CA4300W, NP-CA4305X, NP-CA4400X, NP-CD2125X, NP-CD2200W, NP-CD2300U, NP-CD2310X, NP-CR2105X, NP-CR2200X, NP-CR2205W, NP-CR2300U, NP-CR2300W, NP-CR2315X, NP-CR2400X, NP-MC333XG, NP-MC363XG, NP-MC393WJL, NP-MC423W, NP-MC423WG, NP-MC453X, NP-MC453X, NP-MC453XG, NP-MC453XJL, NP-ME383WG, NP-ME403U, NP-ME403UG, NP-ME403UJL, NP-ME423W, NP-ME423WG, NP-ME423WJL, NP-ME453X, NP-ME453XG, NP-CB4400USL, NP-CB4400WSL, NP-CB4510UL, NP-CB4510WL, NP-CB4510XL, NP-CB4550USL, NP-CB6700UL, NP-CG6510UL, NP-PE456USL, NP-PE456USLG, NP-PE456USLJL, NP-PE456WSLG, NP-PE506UL, NP-PE506ULG, NP-PE506ULJL, NP-PE506WL, NP-PE506WLG, NP-PE506WLJL) allows an attacker to cause a denial-of-service (DoS) condition via SNMP service. |
| A token is created using the username, current date/time, and a fixed
AES-128 encryption key, which is the same across all installations. |
| A vulnerability in the ipsecmgr process of Cisco ASR 5000 Series Software (StarOS) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition.
This vulnerability is due to insufficient validation of incoming Internet Key Exchange Version 2 (IKEv2) packets. An attacker could exploit this vulnerability by sending specifically malformed IKEv2 packets to an affected device. A successful exploit could allow the attacker to cause the ipsecmgr process to restart, which would disrupt ongoing IKE negotiations and result in a temporary DoS condition.Cisco has released software updates that address this vulnerability. There are no workarounds that address this vulnerability. |
| A vulnerability in the “Manages app data” functionality of the web application of ctrlX OS allows a remote authenticated (lowprivileged) attacker to execute arbitrary client-side code in the context of another user's browser via multiple crafted HTTP requests. |
| User-controlled chunkSize metadata from MongoDB lacks appropriate validation allowing malformed GridFS metadata to overflow the bounding container. |
| A vulnerability was found in Thinkware Car Dashcam F800 Pro up to 20250226. It has been declared as problematic. This vulnerability affects unknown code of the component Device Registration Handler. The manipulation leads to use of default credentials. It is possible to launch the attack on the physical device. The complexity of an attack is rather high. The exploitation appears to be difficult. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A security issue exists within DataMosaix™ Private Cloud, allowing attackers to bypass MFA during setup and obtain a valid login-token cookie without knowing the users password. This vulnerability occurs when MFA is enabled but not completed within a 7-day period. |
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. |
| An issue in OneTrust SDK v.6.33.0 allows a local attacker to cause a denial of service via the Object.setPrototypeOf, __proto__, and Object.assign components. NOTE: this is disputed by the Supplier who does not agree it is a prototype pollution vulnerability. |
| Write what were condition within AMD CPUs may allow an admin-privileged attacker to modify the configuration of the CPU pipeline potentially resulting in the corruption of the stack pointer inside an SEV-SNP guest. |
| COMMAX CVD-Axx DVR 5.1.4 contains weak default administrative credentials that allow remote password attacks and disclose RTSP stream. Attackers can exploit this by sending a POST request with the 'passkey' parameter set to '1234', allowing them to access the web control panel. |
| A vulnerability classified as critical has been found in Sony SNC-M1, SNC-M3, SNC-RZ25N, SNC-RZ30N, SNC-DS10, SNC-CS3N and SNC-RX570N up to 1.30. This affects an unknown part of the component Administrative Interface. The manipulation leads to use of default credentials. It is possible to initiate the attack remotely. The complexity of an attack is rather high. The exploitability is told to be difficult. The exploit has been disclosed to the public and may be used. The real existence of this vulnerability is still doubted at the moment. It is recommended to change the configuration settings. The vendor was contacted early about this issue. They confirmed the existence but pointed out that they "have published the 'Hardening Guide' on the Web from July 2018 to January 2025 and have thoroughly informed customers of the recommendation to change their initial passwords". |
| Archer 6.11.00204.10014 allows attackers to execute arbitrary code via crafted system inputs that would be exported into the CSV and be executed after the user opened the file with compatible applications. NOTE: the Supplier does not accept this as a valid vulnerability report against their product. |
| A malformed 802.15.4 packet causes a buffer overflow to occur leading to an assert and a denial of service. A watchdog reset clears the error condition automatically. |
| A prototype pollution in the lib.set function of dref v0.1.2 allows attackers to cause a Denial of Service (DoS) via supplying a crafted payload. |
| In barebox before 2025.01.0, ext4fs_read_symlink has an integer overflow for zalloc (adding one to an le32 variable) via a crafted ext4 filesystem with an inode size of 0xffffffff, resulting in a malloc of zero and resultant memory overwrite, a related issue to CVE-2024-57256. |
| The Cloud MQTT service of the affected products supports wildcard topic
subscription which could allow an attacker to obtain sensitive
information from tapping the service communications. |
| A Denial of Service in CLFS.sys in Microsoft Windows 10, Windows 11, Windows Server 2016, Windows Server 2019, and Windows Server 2022 allows a malicious authenticated low-privilege user to cause a Blue Screen of Death via a forced call to the KeBugCheckEx function. |
| A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. |