| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In WODESYS WD-R608U router (also known as WDR122B V2.0 and WDR28) due to lack of authentication in the configuration change module in the adm.cgi endpoint, the unauthenticated attacker can execute commands including backup creation, device restart and resetting the device to factory settings.
The vendor was notified early about this vulnerability, but didn't respond with the details of vulnerability or vulnerable version range. Only version WDR28081123OV1.01 was tested and confirmed as vulnerable, other versions were not tested and might also be vulnerable. |
| Rasa Pro is a framework for building scalable, dynamic conversational AI assistants that integrate large language models (LLMs). A vulnerability has been identified in Rasa Pro where voice connectors in Rasa Pro do not properly implement authentication even when a token is configured in the credentials.yml file. This could allow an attacker to submit voice data to the Rasa Pro assistant from an unauthenticated source. This issue has been patched for audiocodes, audiocodes_stream, and genesys connectors in versions 3.9.20, 3.10.19, 3.11.7 and 3.12.6. |
| Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code. |
| Built-in SMS-configuration command in Forever KidsWatch Call Me KW50 R36_YDR_A3PW_GM7S_V1.0_2019_07_15_16.19.24_cob_h and Forever KidsWatch Call Me 2 KW-60 R36CW_YDE_S4_A29_2_V1.0_2023.05.24_22.49.44_cob_b allows malicious users to change the device IMEI-number which allows for forging the identity of the device. |
| Beward N100 M2.1.6.04C014 contains an unauthenticated vulnerability that allows remote attackers to access live video streams without credentials. Attackers can directly retrieve the camera's RTSP stream by exploiting the lack of authentication in the video access mechanism. |
| Missing authentication for critical function issue exists in I-O DATA network attached hard disk 'HDL-T Series' firmware Ver.1.21 and earlier. If exploited, a remote unauthenticated attacker may change the product settings. |
| PutongOJ is online judging software. Prior to version 2.1.0-beta.1, unprivileged users can escalate privileges by constructing requests. This can lead to unauthorized access, enabling users to perform admin-level operations, potentially compromising sensitive data and system integrity. This problem has been fixed in v2.1.0.beta.1. As a workaround, one may apply the patch from commit `211dfe9` manually. |
| Missing Authentication for Critical Function vulnerability in ABB ALS-mini-s4 IP, ABB ALS-mini-s8 IP.This issue affects .
All firmware versions with the Serial Number from 2000 to 5166 |
| The software tools used by service personnel to test & calibrate the ventilator do not support user authentication. An attacker with access to the Service PC where the tools are installed could obtain diagnostic information through the test tool or manipulate the ventilator's settings and embedded software via the calibration tool, without having to authenticate to either tool. This could result in unauthorized disclosure of information and/or have unintended impacts on device settings and performance. |
| The vulnerability allows an attacker to bypass the authentication requirements for a specific PAM endpoint. |
| Swissphone DiCal-RED 4009 devices allow a remote attacker to gain a root shell via TELNET without authentication. |
| Akka.NET is a .NET port of the Akka project from the Scala / Java community. In all versions of Akka.Remote from v1.2.0 to v1.5.51, TLS could be enabled via our `akka.remote.dot-netty.tcp` transport and this would correctly enforce private key validation on the server-side of inbound connections. Akka.Remote, however, never asked the outbound-connecting client to present ITS certificate - therefore it's possible for untrusted parties to connect to a private key'd Akka.NET cluster and begin communicating with it without any certificate. The issue here is that for certificate-based authentication to work properly, ensuring that all members of the Akka.Remote network are secured with the same private key, Akka.Remote needed to implement mutual TLS. This was not the case before Akka.NET v1.5.52. Those who run Akka.NET inside a private network that they fully control or who were never using TLS in the first place are now affected by the bug. However, those who use TLS to secure their networks must upgrade to Akka.NET V1.5.52 or later. One patch forces "fail fast" semantics if TLS is enabled but the private key is missing or invalid. Previous versions would only check that once connection attempts occurred. The second patch, a critical fix, enforces mutual TLS (mTLS) by default, so both parties must be keyed using the same certificate. As a workaround, avoid exposing the application publicly to avoid the vulnerability having a practical impact on one's application. However, upgrading to version 1.5.52 is still recommended by the maintainers. |
| A vulnerability has been identified in CPCI85 Central Processing/Communication (All versions < V5.40), SICORE Base system (All versions < V1.4.0). Affected devices allow a remote authenticated user or an unauthenticated user with physical access to downgrade the firmware of the device. This could allow an attacker to downgrade the device to older versions with known vulnerabilities. |
| An attacker could modify or disable settings, disrupt fuel monitoring
and supply chain operations, leading to disabling of ATG monitoring.
This would result in potential safety hazards in fuel storage and
transportation. |
| An unauthenticated user with management network access can get and
modify the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20)
configuration. The device has two web servers that expose unauthenticated REST APIs on the management network (TCP
ports 8084 and 8086). An attacker can use these APIs to get access to all system settings, modify the configuration
and execute some commands (e.g., system reboot). |
| Insufficient authentication in user account management in Yugabyte Platform allows local network attackers with a compromised user session to change critical security information without re-authentication. An attacker with user session and access to application can modify settings such as password and email without being prompted for the current password, enabling account takeover. |
| OMNTEC Proteus Tank Monitoring OEL8000III Series
could allow an attacker to perform administrative actions without proper authentication. |
| DuraComm SPM-500 DP-10iN-100-MU
lacks access controls for a function that should require user authentication. This could allow an attacker to repeatedly reboot the device. |
| In version 0.4.1 of danswer-ai/danswer, a vulnerability exists where a basic user can create credentials and link them to an existing connector. This issue arises because the system allows an unauthenticated attacker to sign up with a basic account and perform actions that should be restricted to admin users. This can lead to excessive resource consumption, potentially resulting in a Denial of Service (DoS) and other significant issues, impacting the system's stability and security. |
| An issue in Casa Systems NTC-221 version 2.0.99.0 and before allows a remote attacker to execute arbitrary code via a crafted payload to the /www/cgi-bin/nas.cgi component. |