| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| An issue was discovered on LG mobile devices with Android OS 9.0 (Qualcomm SDM450, SDM845, SM6150, and SM8150 chipsets) software. Weak encryption leads to local information disclosure. The LG ID is LVE-SMP-190010 (August 2019). |
| The HTTP Authentication library before 2019-12-27 for Nim has weak password hashing because the default algorithm for libsodium's crypto_pwhash_str is not used. |
| A vulnerability in the software cryptography module of the Cisco Adaptive Security Virtual Appliance (ASAv) and Firepower 2100 Series running Cisco Adaptive Security Appliance (ASA) Software could allow an unauthenticated, remote attacker to cause an unexpected reload of the device that results in a denial of service (DoS) condition. The vulnerability is due to a logic error with how the software cryptography module handles IPsec sessions. An attacker could exploit this vulnerability by creating and sending traffic in a high number of IPsec sessions through the targeted device. A successful exploit could cause the device to reload and result in a DoS condition. |
| In situations where an attacker receives automated notification of the success or failure of a decryption attempt an attacker, after sending a very large number of messages to be decrypted, can recover a CMS/PKCS7 transported encryption key or decrypt any RSA encrypted message that was encrypted with the public RSA key, using a Bleichenbacher padding oracle attack. Applications are not affected if they use a certificate together with the private RSA key to the CMS_decrypt or PKCS7_decrypt functions to select the correct recipient info to decrypt. Fixed in OpenSSL 1.1.1d (Affected 1.1.1-1.1.1c). Fixed in OpenSSL 1.1.0l (Affected 1.1.0-1.1.0k). Fixed in OpenSSL 1.0.2t (Affected 1.0.2-1.0.2s). |
| If an application encounters a fatal protocol error and then calls SSL_shutdown() twice (once to send a close_notify, and once to receive one) then OpenSSL can respond differently to the calling application if a 0 byte record is received with invalid padding compared to if a 0 byte record is received with an invalid MAC. If the application then behaves differently based on that in a way that is detectable to the remote peer, then this amounts to a padding oracle that could be used to decrypt data. In order for this to be exploitable "non-stitched" ciphersuites must be in use. Stitched ciphersuites are optimised implementations of certain commonly used ciphersuites. Also the application must call SSL_shutdown() twice even if a protocol error has occurred (applications should not do this but some do anyway). Fixed in OpenSSL 1.0.2r (Affected 1.0.2-1.0.2q). |
| An encryption key vulnerability on Mitel SIP-DECT wireless devices 8.0 and 8.1 could allow an attacker to launch a man-in-the-middle attack. A successful exploit may allow the attacker to intercept sensitive information. |
| minerstat msOS before 2019-10-23 does not have a unique SSH key for each instance of the product. |
| A vulnerability has been identified in SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0 < V5.0.2), SiNVR/SiVMS Video Server (All versions >= V5.0.2). The streaming service (default port 5410/tcp) of the SiVMS/SiNVR Video Server
applies weak cryptography when exposing device (camera) passwords.
This could allow an unauthenticated remote attacker to read and decrypt
the passwords and conduct further attacks. |
| A missing secure communication definition and an incomplete TLS validation in the upgrade service in B&R Automation Studio versions 4.0.x, 4.1.x, 4.2.x, < 4.3.11SP, < 4.4.9SP, < 4.5.5SP, < 4.6.4 and < 4.7.2 enable unauthenticated users to perform MITM attacks via the B&R upgrade server. |
| ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. If a connection is enabled using such a cipher, an attacker might be able to eavesdrop and/or intercept the connection. |
| A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information. |
| Barco ClickShare Button R9861500D01 devices before 1.9.0 have incorrect Credentials Management. The ClickShare Button implements encryption at rest which uses a one-time programmable (OTP) AES encryption key. This key is shared across all ClickShare Buttons of model R9861500D01. |
| A vulnerability has been identified in Control Center Server (CCS) (All versions < V1.5.0), Control Center Server (CCS) (All versions >= V1.5.0), SiNVR/SiVMS Video Server (All versions < V5.0.0), SiNVR/SiVMS Video Server (All versions >= V5.0.0). Both the SiVMS/SiNVR Video Server and the Control Center Server (CCS) store
user and device passwords by applying weak cryptography.
A local attacker could exploit this vulnerability to extract
the passwords from the user database and/or the device configuration files
to conduct further attacks. |
| An issue was found in Philips Veradius Unity, Pulsera, and Endura Dual WAN Router, Veradius Unity (718132) with wireless option (shipped between 2016-August 2018), Veradius Unity (718132) with ViewForum option (shipped between 2016-August 2018), Pulsera (718095) and Endura (718075) with wireless option (shipped between 26-June-2017 through 07-August 2018), Pulsera (718095) and Endura (718075) with ViewForum option (shipped between 26-June-2017 through 07-August 2018). The router software uses an encryption scheme that is not strong enough for the level of protection required. |
| In Philips IntelliBridge EC40 and EC80, IntelliBridge EC40 Hub all versions, and IntelliBridge EC80 Hub all versions, the SSH server running on the affected products is configured to allow weak ciphers. This could enable an unauthorized attacker with access to the network to capture and replay the session and gain unauthorized access to the EC40/80 hub. |
| An issue was discovered in Lightbend Play Framework 2.5.x through 2.6.23. When configured to make requests using an authenticated HTTP proxy, play-ws may sometimes, typically under high load, when connecting to a target host using https, expose the proxy credentials to the target host. |
| An issue was discovered in Intesync Solismed 3.3sp1. An flaw in the encryption implementation exists, allowing for all encrypted data stored within the database to be decrypted. |
| Use of hard-coded cryptographic key vulnerability in August Connect Wi-Fi Bridge App, Connect Firmware allows an attacker to decrypt an intercepted payload containing the Wi-Fi network authentication credentials. This issue affects: August Connect Wi-Fi Bridge App version v10.11.0 and prior versions on Android. August Connect Firmware version 2.2.12 and prior versions. |
| STMicroelectronics ST33TPHF2ESPI TPM devices before 2019-09-12 allow attackers to extract the ECDSA private key via a side-channel timing attack because ECDSA scalar multiplication is mishandled, aka TPM-FAIL. |
| On Supermicro H11, H12, M11, X9, X10, and X11 products, a combination of encryption and authentication problems in the virtual media service allows capture of BMC credentials and data transferred over virtual media devices. Attackers can use captured credentials to connect virtual USB devices to the server managed by the BMC. |