| The DNP3 driver in IOServer drivers 1.0.19.0 allows remote attackers to cause a denial of service (infinite loop) or obtain unspecified control via crafted data to TCP port 20000. |
| The master-station DNP3 driver before driver19.exe, and Beta2041.exe, in IOServer allows remote attackers to cause a denial of service (infinite loop) via crafted DNP3 packets to TCP port 20000. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow remote attackers to cause a denial of service (infinite loop) via a crafted DNP3 TCP packet. |
| Schweitzer Engineering Laboratories (SEL) SEL-2241, SEL-3505, and SEL-3530 RTAC master devices allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The DNP Master Driver in Software Toolbox TOP Server before 5.12.140.0 allows remote attackers to cause a denial of service (master-station infinite loop) via crafted DNP3 packets to TCP port 20000 and allows physically proximate attackers to cause a denial of service (master-station infinite loop) via crafted input over a serial line. |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows remote attackers to cause a denial of service (reboot or link outage) via a crafted DNP3 TCP packet. |
| Cooper Power Systems Cybectec DNP3 Master OPC Server allows remote attackers to cause a denial of service (unhandled exception and process crash) via unspecified vectors. |
| The DNP3 component in Cooper Power Systems SMP 4, 4/DP, and 16 gateways allows physically proximate attackers to cause a denial of service (reboot or link outage) via crafted input over a serial line. |
| The DNP Master Driver in Alstom e-terracontrol 3.5, 3.6, and 3.7 allows physically proximate attackers to cause a denial of service (infinite loop and DNP3 service disruption) via crafted input over a serial line. |
| NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow remote attackers to cause a denial of service (driver crash and process restart) via a crafted DNP3 TCP packet. |
| NovaTech Orion Substation Automation Platform OrionLX DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier and Orion5/Orion5r DNP Master 1.27.38 and DNP Slave 1.23.10 and earlier allow physically proximate attackers to cause a denial of service (driver crash and process restart) via crafted input over a serial line. |
| The (1) Catapult DNP3 I/O driver before 7.2.0.60 and the (2) GE Intelligent Platforms Proficy DNP3 I/O driver before 7.20k, as used in DNPDrv.exe (aka the DNP master station server) in GE Intelligent Platforms Proficy HMI/SCADA - CIMPLICITY and iFIX, allow physically proximate attackers to cause a denial of service (infinite loop) via crafted input over a serial line. |
| The DNP3 service in the Outstation component on Elecsys Director Gateway devices with kernel 2.6.32.11ael1 and earlier allows remote attackers to cause a denial of service (CPU consumption and communication outage) via crafted input. |
| MatrikonOPC SCADA DNP3 OPC Server 1.2.2.0 and earlier allows remote attackers to cause a denial of service (infinite loop) via a malformed DNP3 packet. |
| The XSS Auditor in Google Chrome before 27.0.1453.93 might allow remote attackers to obtain sensitive information via unspecified vectors. |
| Use-after-free vulnerability in Google Chrome before 28.0.1500.71 allows remote attackers to cause a denial of service or possibly have unspecified other impact via vectors related to the handling of input. |
| Google Chrome before 28.0.1500.71 does not properly determine the circumstances in which a renderer process can be considered a trusted process for sign-in and subsequent sync operations, which makes it easier for remote attackers to conduct phishing attacks via a crafted web site. |
| The web portal in Cisco Unified Communications Manager (Unified CM) allows remote authenticated users to obtain sensitive stack-trace information via unspecified vectors that trigger a stack exception, aka Bug ID CSCug34854. |
| The web service framework in Cisco WAAS Software 4.x and 5.x before 5.0.3e, 5.1.x before 5.1.1c, and 5.2.x before 5.2.1 in a Central Manager (CM) configuration allows remote attackers to execute arbitrary code via a crafted POST request, aka Bug ID CSCuh26626. |
| The Cisco Unified IP Phone 8945 with software 9.3(2) allows remote attackers to cause a denial of service (device hang) via a malformed PNG file, aka Bug ID CSCud04270. |