Export limit exceeded: 366301 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 366301 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 10809 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Export limit exceeded: 21181 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (21181 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-21979 2026-04-15 5.3 Medium
An out of bounds write vulnerability in the AMD Radeon™ user mode driver for DirectX® 11 could allow an attacker with access to a malformed shader to potentially achieve arbitrary code execution.
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2025-20617 2026-04-15 N/A
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in UD-LT2 firmware Ver.1.00.008_SE and earlier. If an attacker logs in to the affected product with an administrative account and manipulates requests for a certain screen operation, an arbitrary OS command may be executed. This vulnerability was reported on a different screen operation from CVE-2025-26856.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-22033 2026-04-15 6.3 Medium
The OBS service obs-service-download_url was vulnerable to a command injection vulnerability. The attacker could provide a configuration to the service that allowed to execute command in later steps
CVE-2024-52320 1 Planet Technology Corp 1 Wgs-804hpt Firmware 2026-04-15 9.8 Critical
The affected product is vulnerable to a command injection. An unauthenticated attacker could send commands through a malicious HTTP request which could result in remote code execution.
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-53992 1 Emd115 1 Unzip Bot 2026-04-15 N/A
unzip-bot is a Telegram bot to extract various types of archives. Users could exploit unsanitized inputs to inject malicious commands that are executed through subprocess.Popen with shell=True. Attackers can exploit this vulnerability using a crafted archive name, password, or video name. This vulnerability is fixed in 7.0.3a.
CVE-2025-20016 2026-04-15 7.2 High
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340/D440 provided by Y'S corporation. A user with an administrative privilege who logged in to the web management page of the affected product may execute an arbitrary OS command.
CVE-2025-20014 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2025-1883 2026-04-15 7.8 High
Out-Of-Bounds Write vulnerability exists in the OBJ file reading procedure in SOLIDWORKS eDrawings on Release SOLIDWORKS Desktop 2025. This vulnerability could allow an attacker to execute arbitrary code while opening a specially crafted OBJ file.
CVE-2024-1848 2026-04-15 7.8 High
Heap-based Buffer Overflow, Memory Corruption, Out-Of-Bounds Read, Out-Of-Bounds Write, Stack-based Buffer Overflow, Type Confusion, Uninitialized Variable, Use-After-Free vulnerabilities exist in the file reading procedure in SOLIDWORKS Desktop on Release SOLIDWORKS 2024. These vulnerabilities could allow an attacker to execute arbitrary code while opening a specially crafted CATPART, DWG, DXF, IPT, JT, SAT, SLDDRW, SLDPRT, STL, STP, X_B or X_T file.
CVE-2024-43655 2026-04-15 N/A
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The attacker will first need to find the name of the script, and needs a (low privilege) account to gain access to the script, or convince a user with such access to execute a request to it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2023-7304 1 Ruijie 1 Rg-uac 2026-04-15 N/A
Ruijie RG-UAC Application Management Gateway contains a command injection vulnerability via the 'nmc_sync.php' interface. An unauthenticated attacker able to reach the affected endpoint can inject shell commands via crafted request data, causing the application to execute arbitrary commands on the host. Successful exploitation can yield full control of the application process and may lead to system-level access depending on the service privileges. VulnCheck has observed this vulnerability being targeted by the RondoDox botnet campaign.
CVE-2024-25568 2026-04-15 8.8 High
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent unauthenticated attacker to execute arbitrary OS commands by sending a specially crafted request to the product. Affected products and versions are as follows: WRC-X3200GST3-B v1.25 and earlier, WRC-G01-W v1.24 and earlier, and WMC-X1800GST-B v1.41 and earlier. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B".
CVE-2024-43653 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-25579 1 Elecom 10 Wmc-x1800gst-b Firmware, Wrc-1167gs2-b Firmware, Wrc-1167gs2h-b Firmware and 7 more 2026-04-15 6.8 Medium
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent attacker with an administrative privilege to execute arbitrary OS commands by sending a specially crafted request to the product. Note that WMC-X1800GST-B is also included in e-Mesh Starter Kit "WMC-2LX-B".
CVE-2024-43652 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701 Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services.
CVE-2024-9139 1 Moxa 8 Edf-g1002-bp Firmware, Edr-8010 Firmware, Edr-810 Firmware and 5 more 2026-04-15 7.2 High
The affected product permits OS command injection through improperly restricted commands, potentially allowing attackers to execute arbitrary code.