Export limit exceeded: 22528 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (22528 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-43688 2 Openbsd, Vixie 2 Openbsd, Cron 2026-04-15 7.3 High
cron/entry.c in vixie cron before 9cc8ab1, as used in OpenBSD 7.4 and 7.5, allows a heap-based buffer underflow and memory corruption. NOTE: this issue was introduced during a May 2023 refactoring.
CVE-2024-43657 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: High. However, the attacker will need a (low privilege) account to gain access to the action.exe CGI binary and upload the crafted firmware file, or convince a user with such access to upload it. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-47919 2026-04-15 9.8 Critical
Tiki Wiki CMS – CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43654 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability in Iocharger firmware for AC models allows OS Command Injection as root This issue affects all Iocharger AC EV charger models on a firmware version before 25010801. Likelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-43648 2026-04-15 8.8 High
Command injection in the <redacted> parameter of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). If is a full system compromise, potentially fully compromising confidentiality, integrity and availability of the devicer (VC:H/VI:H/VA:H).  A compromised charger can be used to "pivot" onto networks that should otherwise be closed, cause a low confidentiality and interity impact on subsequent systems. (SC:L/SI:L/SA:H). Because this device is an EV charger handing significant amounts of power, we suspect this vulnerability can have a safety impact (S:P). The attack can be automated (AU:Y).
CVE-2025-2071 2026-04-15 N/A
A critical OS Command Injection vulnerability has been identified in the FAST LTA Silent Brick WebUI, allowing remote attackers to execute arbitrary operating system commands via specially crafted input. This vulnerability arises due to improper handling of untrusted input, which is passed directly to system-level commands without adequate sanitization or validation. Successful exploitation could allow attackers to execute arbitrary commands on the affected system, potentially resulting in unauthorized access, data leakage, or full system compromise. Affected WebUI parameters are "hd" and "pi".
CVE-2025-60017 1 Unitree 4 B2, G1, Go2 and 1 more 2026-04-15 8.2 High
Unitree Go2, G1, H1, and B2 devices through 2025-09-20 allow root OS command injection via the hostapd_restart.sh wifi_ssid or wifi_pass parameter (within restart_wifi_ap and restart_wifi_sta).
CVE-2024-43649 2026-04-15 8.8 High
Authenticated command injection in the filename of a <redacted>.exe request leads to remote code execution as the root user. This issue affects Iocharger firmware for AC models before version 24120701. Likelihood: Moderate – This action is not a common place for command injection vulnerabilities to occur. Thus, an attacker will likely only be able to find this vulnerability by reverse-engineering the firmware or trying it on all <redacted> fields. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a payload. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete files and services. CVSS clarification: This attack can be performed over any network conenction serving the web interfacr (AV:N), and there are not additional mitigating measures that need to be circumvented (AC:L) or other prerequisites (AT:N). The attack does require privileges, but the level does not matter (PR:L), there is no user interaction required (UI:N). The attack leeds to a full compromised of the charger (VC:H/VI:H/VA:H) and a compromised charger can be used to "pivot" to networks that should normally not be reachable (SC:L/SI:L/SA:H). Because this is an EV chargers with significant pwoer, there is a potential safety imp0act (S:P). THis attack can be automated (AU:Y).
CVE-2024-47897 2026-04-15 8.8 High
Software installed and run as a non-privileged user may conduct improper GPU system calls resulting in platform instability and reboots.
CVE-2025-20014 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with version information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2024-47918 2026-04-15 6.1 Medium
Tiki Wiki CMS – CWE-80: Improper Neutralization of Script-Related HTML Tags in a Web Page (Basic XSS)
CVE-2024-1624 2026-04-15 9.4 Critical
An OS Command Injection vulnerability affecting documentation server on 3DEXPERIENCE from Release 3DEXPERIENCE R2022x through Release 3DEXPERIENCE R2024x, SIMULIA Abaqus from Release 2022 through Release 2024, SIMULIA Isight from Release 2022 through Release 2024 and CATIA Composer from Release R2023 through Release R2024. A specially crafted HTTP request can lead to arbitrary command execution.
CVE-2025-5943 1 Microdicom 1 Dicom Viewer 2026-04-15 8.8 High
MicroDicom DICOM Viewer suffers from an out-of-bounds write vulnerability. Remote attackers are able to exploit this issue to potentially execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit the vulnerability in that the user must either visit a malicious website or open a malicious DICOM file locally.
CVE-2024-42502 1 Arubanetworks 1 Arubaos 2026-04-15 7.2 High
Authenticated command injection vulnerability exists in the ArubaOS command line interface. Successful exploitation of this vulnerability result in the ability to inject shell commands on the underlying operating system.
CVE-2025-44635 2026-04-15 9.8 Critical
There are multiple unauthorized remote command execution vulnerabilities in the H3C ER2200G2, ERG2-450W, ERG2-1200W, ERG2-1350W, NR1200W series routers before ERG2AW-MNW100-R1117; H3C ER3100G2, ER3200G2, ER3260G2, ER5100G2, ER5200G2, ER6300G2, ER8300G2, ER8300G2-X series routers before ERHMG2-MNW100-R1126; GR3200, GR5200, GR8300 and other series routers before MiniGR1B0V100R018L50; GR-1800AX before MiniGRW1B0V100R009L50; GR-3000AX before SWBRW1A0V100R007L50; and GR-5400AX before SWBRW1B0V100R009L50. Attackers can bypass authentication by including specially crafted text in the request URL or message header, and then inject arbitrary malicious commands into some fields related to ACL access control list and user group functions and execute to obtain the highest ROOT privileges of remote devices, thereby completely taking over the remote target devices.
CVE-2010-20059 1 Ixsystems 1 Freenas 2026-04-15 N/A
FreeNAS 0.7.2 prior to revision 5543 includes an unauthenticated command‐execution backdoor in its web interface. The exec_raw.php script exposes a cmd parameter that is passed directly to the underlying shell without sanitation.
CVE-2025-20061 1 Myscada 1 Mypro Manager 2026-04-15 9.8 Critical
mySCADA myPRO does not properly neutralize POST requests sent to a specific port with email information. This vulnerability could be exploited by an attacker to execute arbitrary commands on the affected system.
CVE-2024-13089 2026-04-15 7.2 High
An OS command injection vulnerability within the update functionality may allow an authenticated administrator to execute unauthorized arbitrary OS commands. Users with administrative privileges may upload update packages to upgrade the versions of Nozomi Networks Guardian and CMC. While these updates are signed and their signatures are validated prior to installation, an improper signature validation check has been identified. This issue could potentially enable users to execute commands remotely on the appliance, thereby impacting confidentiality, integrity, and availability.
CVE-2025-2367 2026-04-15 6.3 Medium
A vulnerability has been found in Oiwtech OIW-2431APGN-HP 2.5.3-B20131128 and classified as critical. This vulnerability affects unknown code of the file /boafrm/formScript of the component Personal Script Submenu. The manipulation leads to os command injection. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.