Export limit exceeded: 17094 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (17094 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2025-26409 | 2026-04-15 | 6.8 Medium | ||
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. | ||||
| CVE-2024-23194 | 1 Gallagher | 1 Command Centre | 2026-04-15 | 3.3 Low |
| Improper output Neutralization for Logs (CWE-117) in the Command Centre API Diagnostics Endpoint could allow an attacker limited ability to modify Command Centre log files. This issue affects: Gallagher Command Centre v9.10 prior to vEL9.10.1268 (MR1). | ||||
| CVE-2025-40927 | 2026-04-15 | 7.3 High | ||
| CGI::Simple versions before 1.282 for Perl has a HTTP response splitting flaw This vulnerability is a confirmed HTTP response splitting flaw in CGI::Simple that allows HTTP response header injection, which can be used for reflected XSS or open redirect under certain conditions. Although some validation exists, it can be bypassed using URL-encoded values, allowing an attacker to inject untrusted content into the response via query parameters. As a result, an attacker can inject a line break (e.g. %0A) into the parameter value, causing the server to split the HTTP response and inject arbitrary headers or even an HTML/JavaScript body, leading to reflected cross-site scripting (XSS), open redirect or other attacks. The issue documented in CVE-2010-4410 https://www.cve.org/CVERecord?id=CVE-2010-4410 is related but the fix was incomplete. Impact By injecting %0A (newline) into a query string parameter, an attacker can: * Break the current HTTP header * Inject a new header or entire body * Deliver a script payload that is reflected in the server’s response That can lead to the following attacks: * reflected XSS * open redirect * cache poisoning * header manipulation | ||||
| CVE-2025-3017 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability, which was classified as critical, has been found in TA-Lib up to 0.6.4. This issue affects the function setInputBuffer of the file src/tools/ta_regtest/ta_test_func/test_minmax.c of the component ta_regtest. The manipulation leads to out-of-bounds write. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. The identifier of the patch is 5879180e9070ec35d52948f2f57519713256a0f1. It is recommended to apply a patch to fix this issue. | ||||
| CVE-2024-10498 | 1 Schneider-electric | 1 Powerlogic Hdpm6000 | 2026-04-15 | 6.5 Medium |
| CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could allow an unauthorized attacker to modify configuration values outside of the normal range when the attacker sends specific Modbus write packets to the device which could result in invalid data or loss of web interface functionality. | ||||
| CVE-2025-3791 | 2026-04-15 | 5.3 Medium | ||
| A vulnerability classified as critical was found in symisc UnQLite up to 957c377cb691a4f617db9aba5cc46d90425071e2. This vulnerability affects the function jx9MemObjStore of the file /data/src/benchmarks/unqlite/unqlite.c. The manipulation leads to heap-based buffer overflow. It is possible to launch the attack on the local host. The exploit has been disclosed to the public and may be used. Continious delivery with rolling releases is used by this product. Therefore, no version details of affected nor updated releases are available. | ||||
| CVE-2025-13566 | 1 Jarun | 1 Nnn | 2026-04-15 | 3.3 Low |
| A security vulnerability has been detected in jarun nnn up to 5.1. The impacted element is the function show_content_in_floating_window/run_cmd_as_plugin of the file nnn/src/nnn.c. The manipulation leads to double free. An attack has to be approached locally. The identifier of the patch is 2f07ccdf21e705377862e5f9dfa31e1694979ac7. It is suggested to install a patch to address this issue. | ||||
| CVE-2023-32228 | 2026-04-15 | 4.6 Medium | ||
| A firmware bug which may lead to misinterpretation of data in the AMC2-4WCF and AMC2-2WCF allowing an adversary to grant access to the last authorized user. | ||||
| CVE-2025-40906 | 2026-04-15 | 9.8 Critical | ||
| BSON::XS versions 0.8.4 and earlier for Perl includes a bundled libbson 1.1.7, which has several vulnerabilities. Those include CVE-2017-14227, CVE-2018-16790, CVE-2023-0437, CVE-2024-6381, CVE-2024-6383, and CVE-2025-0755. BSON-XS was the official Perl XS implementation of MongoDB's BSON serialization, but this distribution has reached its end of life as of August 13, 2020 and is no longer supported. | ||||
| CVE-2025-53094 | 2026-04-15 | N/A | ||
| ESPAsyncWebServer is an asynchronous HTTP and WebSocket server library for ESP32, ESP8266, RP2040 and RP2350. In versions up to and including 3.7.8, a CRLF (Carriage Return Line Feed) injection vulnerability exists in the construction and output of HTTP headers within `AsyncWebHeader.cpp`. Unsanitized input allows attackers to inject CR (`\r`) or LF (`\n`) characters into header names or values, leading to arbitrary header or response manipulation. Manipulation of HTTP headers and responses can enable a wide range of attacks, making the severity of this vulnerability high. A fix is available at pull request 211 and is expected to be part of version 3.7.9. | ||||
| CVE-2025-3497 | 2026-04-15 | 8.7 High | ||
| The Linux distribution underlying the Radiflow iSAP Smart Collector (CentOS 7 - VSAP 1.20) is obsolete and reached end of life (EOL) on June 30, 2024. Thus, any unmitigated vulnerability could be exploited to affect this product. | ||||
| CVE-2025-31930 | 2026-04-15 | 8.8 High | ||
| A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger. | ||||
| CVE-2025-2029 | 1 Microdicom | 1 Dicom Viewer | 2026-04-15 | 5.3 Medium |
| A vulnerability was found in MicroDicom DICOM Viewer 2025.1 Build 3321. It has been classified as critical. Affected is an unknown function of the file mDicom.exe. The manipulation leads to memory corruption. The attack needs to be approached locally. It is recommended to upgrade the affected component. The vendor quickly confirmed the existence of the vulnerability and fixed it in the latest beta. | ||||
| CVE-2025-4446 | 1 H3c | 1 Gr-5400ax | 2026-04-15 | 8 High |
| A vulnerability has been found in H3C GR-5400AX up to 100R008 and classified as critical. This vulnerability affects the function Edit_List_SSID of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. The attack needs to be approached within the local network. | ||||
| CVE-2024-25972 | 1 Atsumi | 1 Oet-213h-bts1 | 2026-04-15 | 8.3 High |
| Initialization of a resource with an insecure default vulnerability in OET-213H-BTS1 sold in Japan by Atsumi Electric Co., Ltd. allows a network-adjacent unauthenticated attacker to configure and control the affected product. | ||||
| CVE-2024-21859 | 1 Intel | 1 Processors | 2026-04-15 | 5.3 Medium |
| Improper buffer restrictions in the UEFI firmware for some Intel(R) Processors may allow a privileged user to potentially enable information disclosure via local access. | ||||
| CVE-2025-34141 | 2026-04-15 | N/A | ||
| A reflected cross-site scripting (XSS) vulnerability exists in ETQ Reliance CG (legacy) platform within the `SQLConverterServlet` component. This vulnerability requires user interaction, such as clicking a crafted link, and may result in execution of unauthorized scripts in the user's context. The affected servlet was unnecessarily exposed to authenticated users and has since been disabled in version SE.2025.1. | ||||
| CVE-2025-4440 | 1 H3c | 1 Gr-1800ax | 2026-04-15 | 8 High |
| A vulnerability was found in H3C GR-1800AX up to 100R008 and classified as critical. Affected by this issue is the function EnableIpv6 of the file /goform/aspForm. The manipulation of the argument param leads to buffer overflow. Access to the local network is required for this attack to succeed. The exploit has been disclosed to the public and may be used. | ||||
| CVE-2023-28362 | 1 Redhat | 1 Satellite | 2026-04-15 | 4 Medium |
| The redirect_to method in Rails allows provided values to contain characters which are not legal in an HTTP header value. This results in the potential for downstream services which enforce RFC compliance on HTTP response headers to remove the assigned Location header. | ||||
| CVE-2025-36755 | 1 Cleverdisplay | 1 Blueone | 2026-04-15 | N/A |
| The CleverDisplay BlueOne hardware player is designed with its USB interfaces physically enclosed and inaccessible under normal operating conditions. Researchers demonstrated that, after cicumventing the device’s protective enclosure, it was possible to connect a USB keyboard and press ESC during boot to access the BIOS setup interface. BIOS settings could be viewed but not modified. This behavior slightly increases the attack surface by exposing internal system information (CWE-1244) once the enclosure is removed, but does not allow integrity or availability compromise under standard or tested configurations. | ||||