Export limit exceeded: 51067 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (51067 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2024-12011 | 2026-04-15 | 7.6 High | ||
| A CWE-126 “Buffer Over-read” was discovered affecting the 130.8005 TCP/IP Gateway running firmware version 12h. The information disclosure can be triggered by leveraging a memory leak affecting the web server. A remote unauthenticated attacker can exploit this vulnerability in order to leak valid authentication tokens from the process memory associated to users currently logged to the system and bypass the authentication mechanism. | ||||
| CVE-2023-52971 | 1 Mariadb | 1 Mariadb | 2026-04-15 | 4.9 Medium |
| MariaDB Server 10.10 through 10.11.* and 11.0 through 11.4.* crashes in JOIN::fix_all_splittings_in_plan. | ||||
| CVE-2024-45351 | 2026-04-15 | 7.8 High | ||
| A code execution vulnerability exists in the Xiaomi Game center application product. The vulnerability is caused by improper input validation and can be exploited by attackers to execute malicious code. | ||||
| CVE-2024-35532 | 2026-04-15 | 9.1 Critical | ||
| An XML External Entity (XXE) injection vulnerability in Intersec Geosafe-ea 2022.12, 2022.13, and 2022.14 allows attackers to perform arbitrary file reading under the privileges of the running process, make SSRF requests, or cause a Denial of Service (DoS) via unspecified vectors. | ||||
| CVE-2025-2521 | 2026-04-15 | 8.6 High | ||
| The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). An attacker could potentially exploit this vulnerability, leading to an Overread Buffers, which could result in improper index validation against buffer borders leading to remote code execution. Honeywell recommends updating to the most recent version of Honeywell Experion PKS: 520.2 TCU9 HF1 and 530.1 TCU3 HF1 and OneWireless: 322.5 and 331.1. The affected Experion PKS products are C300 PCNT02, C300 PCNT05, FIM4, FIM8, UOC, CN100, HCA, C300PM, and C200E. The Experion PKS versions affected are from 520.1 through 520.2 TCU9 and from 530 through 530 TCU3.The OneWireless WDM affected versions are 322.1 through 322.4 and 330.1 through 330.3. | ||||
| CVE-2024-6350 | 2026-04-15 | 6.5 Medium | ||
| A malformed 802.15.4 packet causes a buffer overflow to occur leading to an assert and a denial of service. A watchdog reset clears the error condition automatically. | ||||
| CVE-2025-26409 | 2026-04-15 | 6.8 Medium | ||
| A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader access can be used to gain a root shell on the device. This issue is fixed in recent firmware versions BSP >= 6.4.1. | ||||
| CVE-2025-2229 | 2026-04-15 | 7.7 High | ||
| A token is created using the username, current date/time, and a fixed AES-128 encryption key, which is the same across all installations. | ||||
| CVE-2025-52883 | 2026-04-15 | 5.3 Medium | ||
| Meshtastic-Android is an Android application for the mesh radio software Meshtastic. Prior to version 2.5.21, an attacker is able to send an unencrypted direct message to a victim impersonating any other node of the mesh. This message will be displayed in the same chat that the victim normally communicates with the other node and it will appear as using PKC, while it is not. This means that the victim will be provided with a false sense of security due to the green padlock displayed when using PKC and they'll read the attacker's message as legitimate. Version 2.5.21 contains a patch for the issue. It is suggested to implement a stricter control on whether a message has been received using PKC or using the shared Meshtastic channel key. Moreover, instead of showing no green padlock icon in the chat with no PKC, consider using an explicit indicator like, for example, the yellow half-open padlock displayed when in HAM mode. This remediation, however, applies to the client applications rather than the Meshtastic firmware. | ||||
| CVE-2025-24876 | 2026-04-15 | 8.1 High | ||
| The SAP Approuter Node.js package version v16.7.1 and before is vulnerable to Authentication bypass. When trading an authorization code an attacker can steal the session of the victim by injecting malicious payload causing High impact on confidentiality and integrity of the application | ||||
| CVE-2025-41706 | 1 Phoenix Contact | 4 Quint4-ups/24dc/24dc/10/eip, Quint4-ups/24dc/24dc/20/eip, Quint4-ups/24dc/24dc/40/eip and 1 more | 2026-04-15 | 5.3 Medium |
| The webserver is vulnerable to a denial of service condition. An unauthenticated remote attacker can craft a special GET request with an over-long content-length to trigger the issue without affecting the core functionality. | ||||
| CVE-2025-3854 | 2026-04-15 | 8 High | ||
| A vulnerability, which was classified as critical, was found in H3C GR-3000AX up to V100R006. Affected is the function EnableIpv6/UpdateWanModeMulti/UpdateIpv6Params/EditWlanMacList/Edit_List_SSID of the file /goform/aspForm of the component HTTP POST Request Handler. The manipulation of the argument param leads to buffer overflow. The attack needs to be initiated within the local network. The exploit has been disclosed to the public and may be used. It is recommended to upgrade the affected component. Other functions might be affected as well. | ||||
| CVE-2015-20111 | 1 Bitcoin | 1 Bitcoin Core | 2026-04-15 | 9.8 Critical |
| miniupnp before 4c90b87, as used in Bitcoin Core before 0.12 and other products, lacks checks for snprintf return values, leading to a buffer overflow and significant data leak, a different vulnerability than CVE-2019-12107. In Bitcoin Core before 0.12, remote code execution was possible in conjunction with CVE-2015-6031 exploitation. | ||||
| CVE-2025-37149 | 1 Hpe | 1 Proliant Rl300 Gen11 | 2026-04-15 | 6 Medium |
| A potential out-of-bound reads vulnerability in HPE ProLiant RL300 Gen11 Server's UEFI firmware. | ||||
| CVE-2025-1073 | 2026-04-15 | 7.5 High | ||
| Panasonic IR Control Hub (IR Blaster) versions 1.17 and earlier may allow an attacker with physical access to load unauthorized firmware onto the device. | ||||
| CVE-2025-59097 | 1 Dormakaba | 1 Access Manager | 2026-04-15 | N/A |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps. This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication: - Re-configure Access Managers (e.g. remove alarming system requirements) - Freely re-configure the inputs and outputs - Open all connected doors permanently - Open all doors for a defined time interval - Change the admin password - and many more Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. | ||||
| CVE-2025-10504 | 1 Abb | 1 Terra Ac Wallbox Jp | 2026-04-15 | 6.1 Medium |
| Heap-based Buffer Overflow vulnerability in ABB Terra AC wallbox.This issue affects Terra AC wallbox: through 1.8.33. | ||||
| CVE-2025-59103 | 1 Dormakaba | 1 Access Manager | 2026-04-15 | N/A |
| The Access Manager 92xx in hardware revision K7 is based on Linux instead of Windows CE embedded in older hardware revisions. In this new hardware revision it was noticed that an SSH service is exposed on port 22. By analyzing the firmware of the devices, it was noticed that there are two users with hardcoded and weak passwords that can be used to access the devices via SSH. The passwords can be also guessed very easily. The password of at least one user is set to a random value after the first deployment, with the restriction that the password is only randomized if the configured date is prior to 2022. Therefore, under certain circumstances, the passwords are not randomized. For example, if the clock is never set on the device, the battery of the clock module has been changed, the Access Manager has been factory reset and has not received a time yet. | ||||
| CVE-2025-34106 | 2026-04-15 | N/A | ||
| A buffer overflow vulnerability exists in PDF Shaper versions 3.5 and 3.6 when converting a crafted PDF file to an image using the 'Convert PDF to Image' functionality. An attacker can exploit this vulnerability by tricking a user into opening a maliciously crafted PDF file, leading to arbitrary code execution under the context of the user. This vulnerability has been verified on Windows XP, 7, 8, and 10 platforms using the PDFTools.exe component. | ||||
| CVE-2025-59109 | 1 Dormakaba | 1 Registration Unit 9002 | 2026-04-15 | N/A |
| The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi). | ||||