Export limit exceeded: 51130 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (51130 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2014-125114 2026-04-15 N/A
A stack-based buffer overflow vulnerability exists in i-Ftp version 2.20 due to improper handling of the Time attribute within Schedule.xml. By placing a specially crafted Schedule.xml file in the i-Ftp application directory, a remote attacker can trigger a buffer overflow during scheduled download parsing, potentially leading to arbitrary code execution or a crash.
CVE-2024-21548 2026-04-15 7.5 High
Versions of the package bun after 0.0.12 and before 1.1.30 are vulnerable to Prototype Pollution due to improper input sanitization. An attacker can exploit this vulnerability through Bun's APIs that accept objects. **Note:** This issue relates to the widely known and actively developed 'Bun' JavaScript runtime. The bun package on NPM at versions 0.0.12 and below belongs to a different and older project that happened to claim the 'bun' name in the past.
CVE-2024-31068 1 Intel 1 Processors 2026-04-15 5.3 Medium
Improper Finite State Machines (FSMs) in Hardware Logic for some Intel(R) Processors may allow privileged user to potentially enable denial of service via local access.
CVE-2025-50130 2026-04-15 7.8 High
A heap-based buffer overflow vulnerability exists in VS6Sim.exe contained in V-SFT and TELLUS provided by FUJI ELECTRIC CO., LTD. Opening V9 files or X1 files specially crafted by an attacker on the affected product may lead to arbitrary code execution.
CVE-2024-36350 2026-04-15 5.6 Medium
A transient execution vulnerability in some AMD processors may allow an attacker to infer data from previous stores, potentially resulting in the leakage of privileged information.
CVE-2024-36357 2026-04-15 5.6 Medium
A transient execution vulnerability in some AMD processors may allow an attacker to infer data in the L1D cache, potentially resulting in the leakage of sensitive information across privileged boundaries.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2024-43802 1 Vim 1 Vim 2026-04-15 4.5 Medium
Vim is an improved version of the unix vi text editor. When flushing the typeahead buffer, Vim moves the current position in the typeahead buffer but does not check whether there is enough space left in the buffer to handle the next characters. So this may lead to the tb_off position within the typebuf variable to point outside of the valid buffer size, which can then later lead to a heap-buffer overflow in e.g. ins_typebuf(). Therefore, when flushing the typeahead buffer, check if there is enough space left before advancing the off position. If not, fall back to flush current typebuf contents. It's not quite clear yet, what can lead to this situation. It seems to happen when error messages occur (which will cause Vim to flush the typeahead buffer) in comnination with several long mappgins and so it may eventually move the off position out of a valid buffer size. Impact is low since it is not easily reproducible and requires to have several mappings active and run into some error condition. But when this happens, this will cause a crash. The issue has been fixed as of Vim patch v9.1.0697. Users are advised to upgrade. There are no known workarounds for this issue.
CVE-2024-43798 1 Jpillora 1 Chisel 2026-04-15 8.6 High
Chisel is a fast TCP/UDP tunnel, transported over HTTP, secured via SSH. The Chisel server doesn't ever read the documented `AUTH` environment variable used to set credentials, which allows any unauthenticated user to connect, even if credentials were set. Anyone running the Chisel server that is using the `AUTH` environment variable to specify credentials to authenticate against is affected by this vulnerability. Chisel is often used to provide an entrypoint to a private network, which means services that are gated by Chisel may be affected. Additionally, Chisel is often used for exposing services to the internet. An attacker could MITM requests by connecting to a Chisel server and requesting to forward traffic from a remote port. This issue has been addressed in release version 1.10.0. All users are advised to upgrade. There are no known workarounds for this vulnerability.
CVE-2024-45296 2 Pillarjs, Redhat 19 Path-to-regexp, Acm, Ansible Automation Platform and 16 more 2026-04-15 7.5 High
path-to-regexp turns path strings into a regular expressions. In certain cases, path-to-regexp will output a regular expression that can be exploited to cause poor performance. Because JavaScript is single threaded and regex matching runs on the main thread, poor performance will block the event loop and lead to a DoS. The bad regular expression is generated any time you have two parameters within a single segment, separated by something that is not a period (.). For users of 0.1, upgrade to 0.1.10. All other users should upgrade to 8.0.0.
CVE-2024-43698 1 Kieback\&peter 10 Ddc4002 Firmware, Ddc4002e Firmware, Ddc4020e Firmware and 7 more 2026-04-15 9.8 Critical
Kieback & Peter's DDC4000 series uses weak credentials, which may allow an unauthenticated attacker to get full admin rights on the system.
CVE-2024-43663 2026-04-15 9.8 Critical
There are many buffer overflow vulnerabilities present in several CGI binaries of the charging station.This issue affects Iocharger firmware for AC model chargers beforeversion 24120701. Likelihood: High – Given the prevalence of these buffer overflows, and the clear error message of the web server, an attacker is very likely to be able to find these vulnerabilities. Impact: Low – Usually, overflowing one of these buffers just causes a segmentation fault of the CGI binary, which causes the web server to return a 502 Bad Gateway error. However the webserver itself is not affected, and no DoS can be achieved. Abusing these buffer overflows in a meaningful way requires highly technical knowledge, especially since ASLR also seems to be enabled on the charging station. However, a skilled attacker might be able to use one of these buffer overflows to obtain remote code execution. CVSS clarification. The attack can be executed over any network connection the station is listening to and serves the web interface (AV:N), and there are no additional security measure sin place that need to be circumvented (AC:L), the attack does not rely on preconditions (AT:N). The attack does require authentication, but the level of authentication is irrelevant (PR:L), it does not require user interaction (UI:N). The attack has a small impact on the availability of the device (VC:N/VI:N/VA:L). There is no impact on subsequent systems. (SC:N/SI:N/SA:N). While this device is an EV charger handing significant amounts of power, we do not expect  this vulnerability to have a safety impact. The attack can be automated (AU:Y).
CVE-2024-43659 2026-04-15 7.2 High
After gaining access to the firmware of a charging station, a file at <redacted> can be accessed to obtain default credentials that are the same across all Iocharger AC model EV chargers. This issue affects Iocharger firmware for AC models before firmware version 25010801. The issue is addressed by requiring a mandatory password change on first login, it is still recommended to change the password on older models. Likelihood: Moderate – The attacker will first have to abuse a code execution or file inclusion vulnerability (for example by using <redacted>.sh) to gain access to the <redacted>.json file, or obtain a firmware dump of the charging station or obtain the firmware via other channels. Impact: Critical – All chargers using Iocharger firmware for AC models started with the same initial password. For models with firmware version before 25010801 a password change was not mandatory. It is therefore very likely that this firmware password is still active on many chargers. These credentials could, once obtained, allow an attacker to log into many Iocharger charging station, and allow them to execute arbitrary commands via the System → Custom page. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, and requires high privileges (PR:H), there is no user interaction required (UI:N). The attack leads to a compromised of the confidentialy of the "super user" credentials of the device (VC:H/VI:N/VA:N), and can subsequently be used to full compromise and other devices (SC:H/SI:H/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-8772 2026-04-15 4.3 Medium
51l3nc3, member of the AXIS OS Bug Bounty Program, has found that the VAPIX API managedoverlayimages.cgi was vulnerable to a race condition attack allowing for an attacker to block access to the overlay configuration page in the web interface of the Axis device. This flaw can only be exploited after authenticating with an operator- or administrator-privileged service account. Axis has released patched AXIS OS versions for the highlighted flaw. Please refer to the Axis security advisory for more information and solution.
CVE-2024-5477 1 Hp 1 Hp 2026-04-15 N/A
A potential security vulnerability has been identified in the System BIOS for some HP PC products which may allow escalation of privilege, arbitrary code execution, denial of service, or information disclosure via a physical attack that requires specialized equipment and knowledge. HP is releasing firmware mitigation for the potential vulnerability.
CVE-2024-55577 2026-04-15 N/A
Stack-based buffer overflow vulnerability exists in Linux Ratfor 1.06 and earlier. When the software processes a file which is specially crafted by an attacker, arbitrary code may be executed. As a result, the attacker may obtain or alter information of the user environment or cause the user environment to become unusable.
CVE-2024-55652 2026-04-15 6.5 Medium
PenDoc is a penetration testing reporting application. Prior to commit 1d4219c596f4f518798492e48386a20c6e9a2fe6, an attacker can write a malicious docx template containing expressions that escape the JavaScript sandbox to execute arbitrary code on the system. An attacker who can control the contents of the template document is able to execute arbitrary code on the system. By default, only users with the `admin` role are able to create or update templates. Commit 1d4219c596f4f518798492e48386a20c6e9a2fe6 patches the issue.
CVE-2024-5632 2026-04-15 N/A
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password. A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2024-29671 2026-04-15 9.8 Critical
Buffer Overflow vulnerability in NEXTU FLATA AX1500 Router v.1.0.2 allows a remote attacker to execute arbitrary code via the POST request handler component.