Vendor Solution
Labcenter recommends ensuring you are using the latest version (9.2 SPO) of the software. Version can be found by looking at the bottom left of the Proteus home page (Version 8 or higher) or by selecting the About ISIS or About ARES option from the Help menu. Update notifications appear in the new and information section of the home page where you can activate the download and installation directly. If you have questions or need help please contact Labcenter or your local distributor.
Tracking
Sign in to view the affected projects.
No advisories yet.
Wed, 08 Jul 2026 14:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Metrics |
ssvc
|
Tue, 07 Jul 2026 23:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| First Time appeared |
Labcenter
Labcenter proteus |
|
| Vendors & Products |
Labcenter
Labcenter proteus |
Tue, 07 Jul 2026 22:15:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The application contains an out-of-bounds write vulnerability that can be exploited by an attacker to cause the program to write data past the end of an allocated memory buffer. This can lead to arbitrary code execution. | |
| Title | Out-of-bounds write in Labcenter Proteus | |
| Weaknesses | CWE-787 | |
| References |
| |
| Metrics |
cvssV4_0
|
Status: PUBLISHED
Assigner: icscert
Published:
Updated: 2026-07-08T13:03:58.052Z
Reserved: 2026-06-03T15:40:50.751Z
Link: CVE-2026-42953
Updated: 2026-07-08T13:03:48.472Z
No data.
No data.
OpenCVE Enrichment
Updated: 2026-07-08T20:45:07Z