If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted.
The following log message can be seen when this issue happens:
agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor>
This issue affects Junos OS on
EX2300, EX3400, EX4000, EX4100 and EX4400
devices:
* all versions before 23.2R2-S7,
* 23.4 versions before 23.4R2-S8,
* 24.2 versions before 24.2R2-S5,
* 24.4 versions before 24.4R2.
Analysis and contextual insights are available on OpenCVE Cloud.
Vendor Solution
The following software releases have been updated to resolve this specific issue: Junos OS: 23.2R2-S7, 23.4R2-S8, 24.2R2-S5, 24.4R2, 25.2R1, and all subsequent releases.
Vendor Workaround
There are no known workarounds for this issue. To reduce the risk of exploitation use access lists or firewall filters to limit access to the device only from trusted hosts and administrators.
Tracking
Sign in to view the affected projects.
No advisories yet.
| Link | Providers |
|---|---|
| https://supportportal.juniper.net/JSA110092 |
|
Thu, 09 Jul 2026 21:45:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of-Service (DoS). If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted. The following log message can be seen when this issue happens: agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor> This issue affects Junos OS on EX2300, EX3400, EX4000, EX4100 and EX4400 devices: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S8, * 24.2 versions before 24.2R2-S5, * 24.4 versions before 24.4R2. | |
| Title | Junos OS: EX Series: Subscribing to an unsupported telemetry sensor path causes fxpc process crash | |
| Weaknesses | CWE-236 | |
| References |
| |
| Metrics |
cvssV3_1
|
Subscriptions
No data.
Status: PUBLISHED
Assigner: juniper
Published:
Updated: 2026-07-09T21:14:11.048Z
Reserved: 2026-06-23T16:27:00.249Z
Link: CVE-2026-57032
No data.
No data.
No data.
OpenCVE Enrichment
No data.